A Method for Determining Customer and Utility Harmonic Contributions at the Point of Common Coupling
نویسندگان
چکیده
A new method is proposed in this paper to determine the harmonic contributions of a customer at the point of common coupling. The method can quantify customer and utility responsibilities for limit violations caused by either harmonic source changes or harmonic impedance changes. It can be implemented in current power quality monitors and digital revenue meters. The method makes it possible to develop fair and consistent billing schemes for harmonic distortion control.
منابع مشابه
An Improved Method for Determining Contribution of Utility and Customer Harmonic Distortions In A Power Distribution System
This paper presents an improved method for determining the share of harmonic distortion generated by utility and customer in a distribution system. The method is based on a Norton equivalent circuit to represent the whole system, modeling the customer side with RLC components by using measured voltage and current at the point of common coupling (PCC). The proposed method evaluates the contribut...
متن کاملEstimating the Harmonic Contributions of Utility and Costumer in a distorted power system
This paper presents an improved method for determining the contribution of harmonic distortion generated by utility and customer at the Point of Common Coupling (PCC) in a distorted power system. For this purpose, first the magnitude and phase of voltage and current at the PCC in each frequency are estimated by adaptive Kalman filter. Then the parameters of Thevenin equivalent circuits of load ...
متن کاملA New Procedure for Determining Current Harmonic Contribution around an Operation Point at PCC Using Load Modelling Based on Crossed Frequency Admittance Matrix
Abstract:Today, one of the important issues of power quality (PQ) in power systems is the current harmonics. Increasing expansion of nonlinear loads at different parts of the electric network makes harmonic distortion flow through the network. This causes the network to have background voltage and current harmonic distortion and even affect on the PQ of linear load performance. Therefore, it is...
متن کاملMODELING RISK OF LOSING A CUSTOMER IN A TWO-ECHELON SUPPLY CHAIN FACING AN INTEGRATED COMPETITOR: A GAME THEORY APPROACH
In a competitive market, customer decision is made to maximize his utility. It can be assumed that risk of losing a supply chain’s customer can be defined based on products utility from customer point of view. This paper takes account of product price and service level as competition criteria. The proposed model is based on non-cooperative game theory, for one-manufacturer and one-retailer supp...
متن کاملAn Approach for Assessing Harmonic Emission Level Based on Robust Partial Least Squares Regression
An approach to evaluate harmonic contributions at the point of common coupling is presented in this paper. The proposed approach is based on robust partial least squares regression, which estimates system harmonic impedance by utilizing the signals of harmonic voltage and current measured synchronously at the point of common coupling. Consequently according to the IEC Technical Report 61000-3-6...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2000