Optimization of a bolometer detector for ITER based on Pt absorber on SiN membrane.
نویسندگان
چکیده
Any plasma diagnostic in ITER must be able to operate at temperatures in excess of 200 °C and neutron loads corresponding to 0.1 dpa over its lifetime. To achieve this aim for the bolometer diagnostic, a miniaturized metal resistor bolometer detector based on Pt absorbers galvanically deposited on SiN membranes is being developed. The first two generations of detectors featured up to 4.5 μm thick absorbers. Results from laboratory tests are presented characterizing the dependence of their calibration constants under thermal loads up to 450 °C. Several detectors have been tested in ASDEX Upgrade providing reliable data but also pointing out the need for further optimization. A laser trimming procedure has been implemented to reduce the mismatch in meander resistances below 1% for one detector and the thermal drifts from this mismatch.
منابع مشابه
Broad-band efficiency calibration of ITER bolometer prototypes using Pt absorbers on SiN membranes.
The energy resolved efficiency of two bolometer detector prototypes for ITER with 4 channels each and absorber thicknesses of 4.5 μm and 12.5 μm, respectively, has been calibrated in a broad spectral range from 1.46 eV up to 25 keV. The calibration in the energy range above 3 eV was performed against previously calibrated silicon photodiodes using monochromatized synchrotron radiation provided ...
متن کاملReliability issues for a bolometer detector for ITER at high operating temperatures.
The first detector prototypes for the ITER bolometer diagnostic featuring a 12.5 μm thick Pt-absorber have been realized and characterized in laboratory tests. The results show linear dependencies of the calibration parameters and are in line with measurements of prototypes with thinner absorbers. However, thermal cycling tests up to 450 °C of the prototypes with thick absorbers demonstrated th...
متن کاملEfficiency calibration of ITER bolometer prototypes Broad-band efficiency calibration of ITER bolometer prototypes using Pt absorbers on SiN membranes
Broad-band efficiency calibration of ITER bolometer prototypes using Pt absorbers on SiN membranes H Meister, M Willmeroth, a) D Zhang, and , A Gottwald, M Krumrey, F Scholze Max-Planck-Institut für Plasmaphysik (IPP), EURATOM Association, Boltzmannstr. 2, 85748 Garching, Germany Max-Planck-Institut für Plasmaphysik (IPP), EURATOM Association, Teilinstitut Greifswald, Wendelsteinstraße 1, 17491...
متن کاملThe ITER bolometer diagnostic: status and plans.
A consortium consisting of four EURATOM Associations has been set up to develop the project plan for the full development of the ITER bolometer diagnostic and to continue urgent R&D activities. An overview of the current status is given, including detector development, line-of-sight optimization, performance analysis as well as the design of the diagnostic components and their integration in IT...
متن کاملA TES Bolometer for THz FT-Spectroscopy
We recently reported on a Transition Edge Sensor (TES) composite bolometer for Fourier Transform spectroscopy which was designed, built and characterized. The design is based on a superconducting thermistor with SQUID readout, SiN membrane technology and a thin film metal mesh absorber which is optimized for the spectral range from 0.1 THz to 3 THz. A noise equivalent power (NEP) of 3.8×10-13 W...