Comparison of flow rate accuracy and consistency between the on-Q, baxter, and ambu pain infusion devices
نویسندگان
چکیده
AIM: Providing analgesia via peripheral nerve catheters attached to an infusion pump is an effective pain management option in children. METHODS: Portable infusion pumps are being used with increased frequency in pediatric patients. Because these pumps are infusing potentially toxic doses of medications, the accuracy and consistency of these devices becomes very important in this patient population. This study is a comparison of the actual delivery volume of local anesthetic of three elastomeric infusion devices approved for patient use in the ambulatory setting. Three brands of disposable elastomeric infusion devices were used (Five On-Q, Five Baxter, and Five Ambu pumps). Each was filled with 200 mL of Ropivicaine 0.1% and connected to a single, end hole infusion catheter and set to infuse at 12 mL/h. The devices were run simultaneously. The fluid delivered was measured every hour with a graduated column over a tenhour period. The ambient temperature BRIEF ARTICLE Online Submissions: http://www.wjgnet.com/esps/ [email protected] doi:10.5313/wja.v3.i1.119 119 March 27, 2014|Volume 3|Issue 1| WJA|www.wjgnet.com World J Anesthesiol 2014 March 27; 3(1): 119-123 ISSN 2218-6182 (online) © 2014 BaishidengPublishing Group Co., Limited. All rights reserved. World Journal of Anesthesiology W J A infusion profile of the individual pump being used. LeRiger M, Bhalla T, Martin D, Bettesworth J, Tobias JD. Comparison of flow rate accuracy and consistency between the on-Q, baxter, and ambu pain infusion devices. World J Anesthesiol 2014; 3(1): 119-123 Available from: URL: http://www.wjgnet.com/2218-6182/full/v3/i1/119.htm DOI: http://dx.doi. org/10.5313/wja.v3.i1.119
منابع مشابه
Comparison of Compressive Properties Between Va-cuum Infusion and Hand Lay-Up Method Toward Bal-sa Core Sandwich Composites
The aim of this work is to evaluate the influence of fabrication methods on the com-pressive properties of sandwich composites using both experimental work and numerical simulations. Two types of sandwich composites with E-glass/Kevlar/polyester resin facings and End-grain balsa wood as core have been produced by vacuum infusion processing (VIP) and hand-lay up (HL) method. Compression tests on...
متن کاملPediatric supraglottic airway devices in clinical practice: A prospective observational study
BACKGROUND Supraglottic airway devices (SGA) are commonly used in pediatric anesthesia and serve as primary or back-up devices for difficult airway management. Most SGA are marketed without proper clinical evaluation. The purpose of this study was to evaluate the performance of the pediatric LMA Supreme™, Air-Q® and Ambu® Aura-i™. METHODS This prospective observational study was performed at ...
متن کاملPRACTICAL PROBLEMS AND THE EFFICACY OF INTRAOSSEOUS INFUSION: SOLVING THE PROBLEMS BY EMPLOYING AN ANIMAL MODEL
In critically ill infants and children, intravascular (IV) access is sometimes very difficult. In such cases intraosseous (IO) infusion should be used as the method of choice. However, in practice, different problems are experienced with this procedure. To overcome the practical problems and to confirm the efficacy of IO infusion in reversing hypovolemic shock, an animal model was used by ...
متن کاملComparison of the effect of chewing mastic and spearmint sugar-free chewing gum on salivary flow rate and pH
BACKGROUND AND AIM: Hyposalivation can cause many difficulties for patients like opportunistic infections such as candidiasis, mouth sores, and dysphagia as well as reduced quality of life (QOL). Methods such as using sugar-free chewing gum are recommended to treat this complication. Mastic is a natural substance and since it has various properties in addition ...
متن کاملبررسی اثر انفوزیون وریدی لیدوکائین حین عمل بر میزان درد بعد از عمل جراحی لاپاراسکوپیک کوله سیستکتومی
Background and Objective: Despite applying new drugs and techniques, many patients experience moderate to severe pain after surgery. Our goal in this study was to determine the effect of intravenous (IV) lidocaine infusion on postoperative pain in laparoscopic cholecystectomy surgery. Materials and Methods: In this double-blind clinical trial a total of 70 candidates for laparoscopic ch...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2014