Dosimetric evaluation of internal shielding in a high dose rate skin applicator
نویسندگان
چکیده
PURPOSE The Valencia HDR applicators are accessories of the microSelectron HDR afterloading system (Nucletron) shaped as truncated cones. The base of the cone is either 2 or 3 cm diameter. They are intended to treat skin lesions, being the typical prescription depth 3 mm. In patients with eyelid lesions, an internal shielding is very useful to reduce the dose to the ocular globe. The purpose of this work was to evaluate the dose enhancement from potential backscatter and electron contamination due to the shielding. MATERIAL AND METHODS Two methods were used: a) Monte Carlo simulation, performed with the GEANT4 code, 2 cm Valencia applicator was placed on the surface of a water phantom in which 2 mm lead slab was located at 3 mm depth; b) radiochromic EBT films, used to verify the Monte Carlo results, positioning the films at 1.5, 3, 5 and 7 mm depth, inside the phantom. Two irradiations, with and without the lead shielding slab, were carried out. RESULTS The Monte Carlo results showed that due to the backscatter component from the lead, the dose level raised to about 200% with a depth range of 0.5 mm. Under the lead the dose level was enhanced to about 130% with a depth range of 1 mm. Two millimeters of lead reduce the dose under the slab with about 60%. These results agree with film measurements within uncertainties. CONCLUSIONS In conclusion, the use of 2 mm internal lead shielding in eyelid skin treatments with the Valencia applicators were evaluated using MC methods and EBT film dosimetry. The minimum bolus thickness that was needed above and below the shielding was 0.5 mm and 1 mm respectively, and the shielding reduced the absorbed dose delivered to the ocular globe by about 60%.
منابع مشابه
Dosimetric pitfalls in the application of shielding disk in breast intraoperative electron radiation therapy
Introduction: Intraoperative electron radiotherapy (IOERT) is an IORT technique in which electron beams with different nominal energies are used for irradiation of microscopic residual of tumor bed after surgery. Application of a shielding disk, which is positioned under the target volume, for protecting the normal tissues such as pectoral muscle, lung, and heart is one of the a...
متن کاملStudy of dosimetric and spatial variations due to applicator positioning during inter-fraction high-dose rate brachytherapy in the treatment of carcinoma of the cervix: A three dimensional dosimetric analysis
Background: This study evaluates dosimetric and spatial variations in inter–fraction applicator positioning in high dose rate (HDR) brachytherapy. Materials and Methods: This study includes 25 retrospective patients of carcinoma of the cervix. Each patient received 5 fractions of HDR intracavitary brachytherapy. High Risk-Clinical Target Volume (HR-CTV) were drawn on CT images. First impl...
متن کاملSimulation of the shielding effects of an applicator on the AAPM TG-43 parameters of CS-137 Selectron LDR brachytherapy sources
Background: The dose rate distribution delivered by a low dose rate 137Cs pellet source, a spherical source used within the source trains of the Selectron gynecological brachytherapy system, was investigated using the MCNP4C Monte Carlo code. Materials and Methods: The calculations were performed in both water and Plexiglas and the absolute dose rate distribution for a single pellet s...
متن کاملCalculation of absorbed dose rate in the lungs, ribs and skin by the mammosite applicator in breast cancer brachytherapy with MCNP
Introduction: Breast cancer is the most common cancer among women. Brachytherapy is one of the ways to treat breast cancer. In brachytherapy treatments, high-dose sources are used in interstitial placement. Here, Iridium-192 is used. This source emits gamma rays with energies ranging from 136 kV to 1060 kV electron volts. The activity of the used spring is 10 Ci. The simulated ...
متن کاملEvaluation of organs at risk dose in the left breast IOERT procedures whit and without shielding disc using monte carlo simulation
Introduction: One of the treatment choices in breast cancer is Intra operative electron beam radiation therapy (IOERT). Due to high dose delivery in this procedure, shielding disk is used to protect organs at risk (OARs). In this study, we evaluate the OARs dose in the breast IOERT using Monte Carlo simulation with and without shielding disk in RANDO phantom. Material and Methods: Simulation ...