Venous cannula performance assessment in a realistic caval tree model.
نویسندگان
چکیده
OBJECTIVES A new caval tree system was designed for realistic in vitro simulation. The objective of our study was to assess cannula performance for virtually wall-less versus standard percutaneous thin-walled venous cannulas in a setting of venous collapse in case of negative pressure. METHODS For a collapsible caval model, a very flexible plastic material was selected, and a model with nine afferent veins was designed according to the anatomy of the vena cava. A flow bench was built including a lower reservoir holding the caval tree, built by taking into account the main afferent vessels and their flow provided by a reservoir 6 cm above. A cannula was inserted in this caval tree and connected to a centrifugal pump that, in turn, was connected to a reservoir positioned 83 cm above the second lower reservoir (after-load = 60 mmHg). Using the same pre-load, the simulated venous drainage for cardiopulmonary bypass was realized using a 24 F wall-less cannula (Smartcanula) and 25 F percutaneous cannula (Biomedicus), and stepwise increased augmentation (1500 RPM, 2000 and 2500 RPM) of venous drainage. RESULTS For the thin wall and the wall-less cannulas, 36 pairs of flow and pressure measurements were realized for three different RPM values. The mean Q-values at 1500, 2000 and 2500 RPM were: 3.98 ± 0.01, 6.27 ± 0.02 and 9.81 ± 0.02 l/min for the wall-less cannula (P <0.0001), versus 2.74 ± 0.02, 3.06 ± 0.05, 6.78 ± 0.02 l/min for the thin-wall cannula (P <0.0001). The corresponding inlet pressure values were: -8.88 ± 0.01, -23.69 ± 0.81 and -70.22 ± 0.18 mmHg for the wall-less cannula (P <0.0001), versus -36.69 ± 1.88, -80.85 ± 1.71 and -101.83 ± 0.45 mmHg for the thin-wall cannula (P <0.0001). The thin-wall cannula showed mean Q-values 37% less and mean P values 26% more when compared with the wall-less cannula (P <0.0001). CONCLUSIONS Our in vitro water test was able to mimic a negative pressure situation, where the wall-less cannula design performs better compared with the traditional thin-wall cannula.
منابع مشابه
Caval collapse during cardiopulmonary bypass: a reproducible bench model.
OBJECTIVES During open heart surgery, so-called atrial chatter, a phenomenon due to right atria and/or caval collapse, is frequently observed. Collapse of the cava axis during cardiopulmonary bypass (CPB) limits venous drainage and may result downstream in reduced pump flow on (lack of volume) and upstream in increased after-load (stagnation), which in turn may both result in reduced or even in...
متن کاملVenous Cannula Positioning in Arterial Deoxygenation During Veno‐Arterial Extracorporeal Membrane Oxygenation—A Simulation Study and Case Report
Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is indicated in reversible life-threatening circulatory failure with or without respiratory failure. Arterial desaturation in the upper body is frequently seen in patients with peripheral arterial cannulation and severe respiratory failure. The importance of venous cannula positioning was explored in a computer simulation model and a cl...
متن کاملTemporary caval stenting improves venous drainage during cardiopulmonary bypass.
OBJECTIVES Assess the benefit of temporary caval stenting for remote venous drainage during cardiopulmonary bypass (CPB). METHODS Temporary caval stenting was realized in bovine experiments (65+/-6 kg) by the means of self-expanding (18F for insertion, 36F in situ) venous cannulas (Smartcanula LLC, Lausanne, Switzerland) with various lengths: 43 cm, 53 cm, 63 cm vs. a standard 28F wire armed ...
متن کاملDiagnosis of inadvertent cannulation of the azygos vein during cardiopulmonary bypass.
Cardiac surgery with cardiopulmonary bypass demands diligence and attention to detail to prevent neurologic injury. Arterial and venous cannulae are used to facilitate cardiopulmonary bypass. The assessment of adequate decompression of the venous circulation is an essential duty of the cardiac surgical team. Modalities for the assessment of adequate regional venous drainage are limited, however...
متن کاملبررسی ارزش تشخیصی میزانCaval index در تعیین فشار ورید مرکزی پایین در مقایسه با روش تهاجمی در بیماران بستری در ICU بیمارستان شهید باهنر کرمان
Introduction: Measurement of central venous pressure can be regarded as a beneficial guide in order to assess a patient's hemodynamic status, specifically in patient with sever sepsis and septic shock, for whom a central venous pressure of less than 8mmhg is considered as an indicator for aggressive intravenous fluid replacement. Therefore, this study aimed to investigate the ultrasonographic e...