Unsedated peroral wireless pH capsule placement vs. standard pH testing: A randomized study and cost analysis

نویسندگان

  • Christopher N Andrews
  • Daniel C Sadowski
  • Adriana Lazarescu
  • Chad Williams
  • Emil Neshev
  • Martin Storr
  • Flora Au
  • Steven J Heitman
چکیده

BACKGROUND Wireless capsule pH-metry (WC) is better tolerated than standard nasal pH catheter (SC), but endoscopic placement is expensive. AIMS to confirm that non-endoscopic peroral manometric placement of WC is as effective and better tolerated than SC and to perform a cost analysis of the available esophageal pH-metry methods. METHODS Randomized trial at 2 centers. Patients referred for esophageal pH testing were randomly assigned to WC with unsedated peroral placement or SC after esophageal manometry (ESM). Primary outcome was overall discomfort with pH-metry. Costs of 3 different pH-metry strategies were analyzed: 1) ESM + SC, 2) ESM + WC and 3) endoscopically placed WC (EGD + WC) using publicly funded health care system perspective. RESULTS 86 patients (mean age 51 ± 2 years, 71% female) were enrolled. Overall discomfort score was less in WC than in SC patients (26 ± 4 mm vs 39 ± 4 mm VAS, respectively, p = 0.012) but there were no significant group differences in throat, chest, or overall discomfort during placement. Overall failure rate was 7% in the SC group vs 12% in the WC group (p = 0.71). Per patient costs ($Canadian) were $1475 for EGD + WC, $1014 for ESM + WC, and $906 for ESM + SC. Decreasing the failure rate of ESM + WC from 12% to 5% decreased the cost of ESM + WC to $991. The ESM + SC and ESM + WC strategies became equivalent when the cost of the WC device was dropped from $292 to $193. CONCLUSIONS Unsedated peroral WC insertion is better tolerated than SC pH-metry both overall and during placement. Although WC is more costly, the extra expense is partially offset when the higher patient and caregiver time costs of SC are considered. TRIAL REGISTRATION Clinicaltrials.gov Identifier NCT01364610.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Gastroesophageal Reflux Disease Using the Bravo Capsule pH System.

Gastroesophageal reflux disease (GERD) is a disease predominantly seen in the West but there is a rising trend in Asia. Ambulatory 24-hour catheter-based pH monitoring has been the de facto gold standard test for GERD that correlates symptoms with acid reflux episodes. However, drawbacks such as patients' discomfort, and catheter displacement render the test as cumbersome and error-prone. The B...

متن کامل

Comparison of esophageal placement of Bravo capsule system under direct endoscopic guidance with conventional placement method

BACKGROUND Conventional placement of a wireless esophageal pH monitoring device in the esophagus requires initial endoscopy to determine the distance to the gastroesophageal junction. Blind placement of the capsule by the Bravo delivery system is followed by repeat endoscopy to confirm placement. Alternatively, the capsule can be placed under direct vision during endoscopy. Currently there are ...

متن کامل

Impact of prolonged 48-h wireless capsule esophageal pH monitoring on diagnosis of gastroesophageal reflux disease and evaluation of the relationship between symptoms and reflux episodes.

CONTEXT Gastroesophageal reflux disease is one of the most common digestive diseases and an important cause of distress to patients. Diagnosis of this condition can require ambulatory pH monitoring. OBJECTIVES To determine the diagnostic yield of a wireless ambulatory pH monitoring system of 48-hours, recording to diagnose daily variability of abnormal esophageal acid exposure and its symptom...

متن کامل

Comparative study of two modes of gastroesophageal reflux measuring: conventional esophageal pH monitoring and wireless pH monitoring.

CONTEXT Esophageal pH monitoring is considered to be the gold standard for the diagnosis of gastroesophageal acid reflux. However, this method is very troublesome and considerably limits the patient's routine activities. Wireless pH monitoring was developed to avoid these restrictions. OBJECTIVE To compare the first 24 hours of the conventional and wireless pH monitoring, positioned 3 cm abov...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2012