Assessment of a fully 3D Monte Carlo reconstruction method for preclinical PET with iodine-124.
نویسندگان
چکیده
Iodine-124 is a radionuclide well suited to the labeling of intact monoclonal antibodies. Yet, accurate quantification in preclinical imaging with I-124 is challenging due to the large positron range and a complex decay scheme including high-energy gammas. The aim of this work was to assess the quantitative performance of a fully 3D Monte Carlo (MC) reconstruction for preclinical I-124 PET. The high-resolution small animal PET Inveon (Siemens) was simulated using GATE 6.1. Three system matrices (SM) of different complexity were calculated in addition to a Siddon-based ray tracing approach for comparison purpose. Each system matrix accounted for a more or less complete description of the physics processes both in the scanned object and in the PET scanner. One homogeneous water phantom and three heterogeneous phantoms including water, lungs and bones were simulated, where hot and cold regions were used to assess activity recovery as well as the trade-off between contrast recovery and noise in different regions. The benefit of accounting for scatter, attenuation, positron range and spurious coincidences occurring in the object when calculating the system matrix used to reconstruct I-124 PET images was highlighted. We found that the use of an MC SM including a thorough modelling of the detector response and physical effects in a uniform water-equivalent phantom was efficient to get reasonable quantitative accuracy in homogeneous and heterogeneous phantoms. Modelling the phantom heterogeneities in the SM did not necessarily yield the most accurate estimate of the activity distribution, due to the high variance affecting many SM elements in the most sophisticated SM.
منابع مشابه
Rabbit internal dosimetry for iodine-131 using GATE Monte Carlo simulation code: a preclinical trial
Introduction: One of the main concerns in administration of radiotracers, especially in therapeutic arm, is the amount of delivered dose to the different organs. Individual variations of anatomy, physiology and underlying pathology in the patients lead to alteration of administered activity. In the current study we preclinically applied internal dosimetry using an animal mod...
متن کاملComparison of Absorbed Fraction of Gamma and Beta Rays of I-124 and I-131radio-Isotopes in Thyroid Gland with Monte Carlo Simulation
I131 is a famous radio-iodine isotope in use for diagnosis and treatment of hyper functioning and cancerous thyroid gland. It is a nuclear reactor product; however nuclear reactor may be unavailable in some areas. Replacement by I-124 may be possible, another iodine isotope producible by cyclotron; a system more available than reactor. Here absorbed fraction of Gamma and Beta rays of...
متن کاملComparison of Absorbed Fraction of Gamma and Beta Rays of I-124 and I-131radio-Isotopes in Thyroid Gland with Monte Carlo Simulation
I131 is a famous radio-iodine isotope in use for diagnosis and treatment of hyper functioning and cancerous thyroid gland. It is a nuclear reactor product; however nuclear reactor may be unavailable in some areas. Replacement by I-124 may be possible, another iodine isotope producible by cyclotron; a system more available than reactor. Here absorbed fraction of Gamma and Beta rays of...
متن کاملPerformance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE
Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...
متن کاملStatistical reconstruction-based scatter correction: a new method for 3D PET
Accurate scatter correction is one of the major problems facing quantitative 3D PET and many methods have been developed for the purpose of reducing the resultant degradation of image contrast and loss of quantitative accuracy. A new scatter correction method called Statistical Reconstruction-Based Scatter Correction (SRBSC) is proposed in this paper and evaluated using Monte Carlo simulations,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physics in medicine and biology
دوره 60 6 شماره
صفحات -
تاریخ انتشار 2015