Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation.

نویسندگان

  • Karl-Heinz Kuck
  • Josep Brugada
  • Alexander Fürnkranz
  • Andreas Metzner
  • Feifan Ouyang
  • K R Julian Chun
  • Arif Elvan
  • Thomas Arentz
  • Kurt Bestehorn
  • Stuart J Pocock
  • Jean-Paul Albenque
  • Claudio Tondo
چکیده

BACKGROUND Current guidelines recommend pulmonary-vein isolation by means of catheter ablation as treatment for drug-refractory paroxysmal atrial fibrillation. Radiofrequency ablation is the most common method, and cryoballoon ablation is the second most frequently used technology. METHODS We conducted a multicenter, randomized trial to determine whether cryoballoon ablation was noninferior to radiofrequency ablation in symptomatic patients with drug-refractory paroxysmal atrial fibrillation. The primary efficacy end point in a time-to-event analysis was the first documented clinical failure (recurrence of atrial fibrillation, occurrence of atrial flutter or atrial tachycardia, use of antiarrhythmic drugs, or repeat ablation) following a 90-day period after the index ablation. The noninferiority margin was prespecified as a hazard ratio of 1.43. The primary safety end point was a composite of death, cerebrovascular events, or serious treatment-related adverse events. RESULTS A total of 762 patients underwent randomization (378 assigned to cryoballoon ablation and 384 assigned to radiofrequency ablation). The mean duration of follow-up was 1.5 years. The primary efficacy end point occurred in 138 patients in the cryoballoon group and in 143 in the radiofrequency group (1-year Kaplan-Meier event rate estimates, 34.6% and 35.9%, respectively; hazard ratio, 0.96; 95% confidence interval [CI], 0.76 to 1.22; P<0.001 for noninferiority). The primary safety end point occurred in 40 patients in the cryoballoon group and in 51 patients in the radiofrequency group (1-year Kaplan-Meier event rate estimates, 10.2% and 12.8%, respectively; hazard ratio, 0.78; 95% CI, 0.52 to 1.18; P=0.24). CONCLUSIONS In this randomized trial, cryoballoon ablation was noninferior to radiofrequency ablation with respect to efficacy for the treatment of patients with drug-refractory paroxysmal atrial fibrillation, and there was no significant difference between the two methods with regard to overall safety. (Funded by Medtronic; FIRE AND ICE ClinicalTrials.gov number, NCT01490814.).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulmonary vein stenosis after second-generation cryoballoon ablation for atrial fibrillation

Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF), especially in paroxysmal 1 AF patients. In addition to a radiofrequency ablation catheter, a cryoballoon has been proven as an effective technology in PVI for AF. Recently several randomized trials have shown that cryoballoon ablation was noninferior to radiofrequency ablation with respect to ef...

متن کامل

Outcomes Of Cryoballoon Ablation Of Atrial Fibrillation: A Comprehensive Review.

Over the last decade, cryoballoon ablation has emerged as an effective alternate strategy to point-by-point radiofrequency ablation for treatment of symptomatic atrial fibrillation. There are several reasons for this. First, the acute and long-term safety and efficacy associated with cryoablation appear comparable to that of radiofrequency ablation in patients with both paroxysmal and also pers...

متن کامل

Cryoballoon Ablation for Atrial Fibrillation

Focal point-by-point radiofrequency catheter ablation has shown considerable success in the treatment of paroxysmal atrial fibrillation. However, it is not without limitations. Recent clinical and preclinical studies have demonstrated that cryothermal ablation using a balloon catheter (Artic Front©, Medtronic CryoCath LP) provides an effective alternative strategy to treating atrial fibrillatio...

متن کامل

Cryoballoon dysfunction indicated by abrupt temperature drop during atrial fibrillation ablation.

Pulmonary vein (PV) isolation remains the cornerstone of atrial fibrillation (AF) ablation. Cryoballoon ablation is shown to be non-inferior to radiofrequency ablation in terms of efficacy and safety among paroxysmal AF patients. In this case, we report an intraprocedural adverse event encountered during cryoballoon ablation. A 46-year-old male patient with symptomatic, paroxysmal AF underwent ...

متن کامل

Cryoballoon or radiofrequency ablation for symptomatic paroxysmal atrial fibrillation: reintervention, rehospitalization, and quality-of-life outcomes in the FIRE AND ICE trial

AIMS The primary safety and efficacy endpoints of the randomized FIRE AND ICE trial have recently demonstrated non-inferiority of cryoballoon vs. radiofrequency current (RFC) catheter ablation in patients with drug-refractory symptomatic paroxysmal atrial fibrillation (AF). The aim of the current study was to assess outcome parameters that are important for the daily clinical management of pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The New England journal of medicine

دوره 374 23  شماره 

صفحات  -

تاریخ انتشار 2016