Comparison of agar dilution, broth microdilution, E-test, disk diffusion, and automated Vitek methods for testing susceptibilities of Enterococcus spp. to vancomycin.

نویسندگان

  • P C Kohner
  • R Patel
  • J R Uhl
  • K M Garin
  • M K Hopkins
  • L T Wegener
  • F R Cockerill
چکیده

An evaluation was undertaken to determine the optimal method for testing the susceptibilities of 100 clinical isolates and two reference strains of Enterococcus spp. to vancomycin in vitro. Six testing methods were studied by using the following media and incubation times: agar screen with the Synergy Quad Plate (Remel, Lenexa, Kans.), an in-house-prepared brain heart infusion (BHI) agar plate, and an in-house-prepared Mueller-Hinton (MH) agar plate, all incubated for 24 or 48 h; broth microdilution (Sensititre Just One Strip; AccuMed International, Inc., West Lake, Ohio) with BHI or cation-adjusted MH broth incubated for 24 or 48 h; agar dilution with BHI or MH agar incubated for 24 or 48 h; epsilometer test (E test; AB BioDisk, Solna, Sweden) with BHI or MH agar incubated for 24 or 48 h; disk diffusion with BHI or MH agar incubated for 24 or 48 h; and the automated Vitek method with the gram-positive susceptibility Staphylococcus aureus card and R02.03 software (bioMerieux, Inc., Hazelwood, Mo.). Growth failures occurred with MH media (n = 6) but not with BHI media. One growth failure occurred with the Vitek method. Results for each testing method for each Enterococcus strain were interpreted as susceptible, intermediate, or resistant according to current National Committee for Clinical Laboratory Standards (NCCLS) criteria and compared to the vancomycin resistance genotype (i.e., vanA, vanB, vanC-1, or vanC-2/3). For all methods, extension of the incubation time from 24 h to 48 h either produced no difference in the results or gave poorer results. The following methods produced no very major or major interpretive errors: broth microdilution with BHI media incubated for 24 h, agar dilution with BHI media incubated for 24 or 48 h, and E test with BHI media incubated for 24 or 48 h. Unacceptable frequencies of very major errors (> 1%) occurred with all methods for which MH media were used. Minor interpretive errors were frequent with all methods. These minor interpretive errors also occurred most frequently with Enterococcus strains with vanC genes, which encoded low-level vancomycin resistance (MIC < or = 8 microg/ml), as opposed to Enterococcus strains which possessed vanA or vanB genes, which encoded higher-level vancomycin resistance (MIC > or = 64 microg/ml). Modification of NCCLS breakpoints, especially for motile Enterococcus spp. (E. casseliflavus, E. flavescens, and E. gallinarum), may resolve this problem; however, in the current study, one E. faecalis strain and one E. faecium strain carried only the vanC gene. The agar screen method may also require reformulation. The current agar screen plate contains 6 microg of vancomycin per ml, which may not detect all low-level resistance associated with vanC genotypes. Nevertheless, the clinical significance of this low-level vancomycin resistance remains unknown.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of five methods, including the PDM Epsilometer test (E test), for antimicrobial susceptibility testing of Pseudomonas aeruginosa.

The antimicrobial susceptibilities of 100 clinical isolates of Pseudomonas aeruginosa to six antipseudomonal antibiotics were tested by five methods: the National Committee for Clinical Laboratory Standards (NCCLS) methods for broth microdilution, agar dilution, and agar disk diffusion; the Vitek Automicrobic System method (Vitek Systems, Hazelwood, Mo.); and the PDM Epsilometer test (E test) (...

متن کامل

Comparison of testing methods for detection of decreased linezolid susceptibility due to G2576T mutation of the 23S rRNA gene in Enterococcus faecium and Enterococcus faecalis.

E-test, Vitek 2, MicroScan, agar dilution, and disk diffusion were compared for detection of decreased linezolid susceptibility due to 23S rRNA gene G2576T mutation among 32 clinical Enterococcus strains initially reported as intermediate or resistant by E-test alone or Vitek 2 confirmed by E-test. Agar and broth dilution methods were in concordance with PCR detection of the mutation, and disk ...

متن کامل

Reliability of the E test for detection of ampicillin, vancomycin, and high-level aminoglycoside resistance in Enterococcus spp.

By comparison with agar dilution results, the E test was investigated for the ability to detect high-level aminoglycoside (gentamicin and streptomycin), ampicillin, and vancomycin resistance among strains representing six enterococcal species. For ampicillin and vancomycin, disk diffusion results also were obtained. No false high-level aminoglycoside resistance occurred, and no false gentamicin...

متن کامل

Comparison of agar dilution, disk diffusion, MicroScan, and Vitek antimicrobial susceptibility testing methods to broth microdilution for detection of fluoroquinolone-resistant isolates of the family Enterobacteriaceae.

Fluoroquinolone resistance appears to be increasing in many species of bacteria, particularly in those causing nosocomial infections. However, the accuracy of some antimicrobial susceptibility testing methods for detecting fluoroquinolone resistance remains uncertain. Therefore, we compared the accuracy of the results of agar dilution, disk diffusion, MicroScan Walk Away Neg Combo 15 convention...

متن کامل

In vitro susceptibility studies of vancomycin-resistant Enterococcus faecalis.

Vancomycin resistance exhibited by Enterococcus faecalis isolates V583, V586, and V587 is described. The vancomycin MICs ranged from 32 to 64 micrograms/ml. Although resistant to vancomycin, the isolates were susceptible to teicoplanin (MIC, less than or equal to 0.5 micrograms/ml). Such a glycopeptide susceptibility profile has not been previously described for E. faecalis. Time kill studies s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 35 12  شماره 

صفحات  -

تاریخ انتشار 1997