Long-term follow-up of morbidity and mortality after aortic valve replacement with a mechanical valve prosthesis.

نویسندگان

  • P Kvidal
  • R Bergström
  • T Malm
  • E Ståhle
چکیده

AIMS The aim of this study was to determine the incidence of valve-related complications in patients with a mechanical aortic valve prosthesis and to identify risk factors for an adverse outcome. METHODS AND RESULTS In the 424 patients, event-free survival rates 5 and 10 years after aortic valve replacement were 62% and 37%, respectively. The linearized incidence of thromboembolic events was 4.4% per patient-year, and of anticoagulant-related haemorrhage 8.5% per patient-year. Advanced NYHA functional class, atrial fibrillation, pure aortic regurgitation and thromboembolism prior to surgery decreased event-free survival. A history of pre-operative thromboembolism increased the risk for a first embolic event after aortic valve replacement (relative hazard [RH] 3.2), but was even more strongly associated with the risk for repeated events (> or =2 events, RH 5.4). After each thromboembolic episode that occurred, the risk for a subsequent one was increased. The risk for at least one, and up to three or more haemorrhages was increased in patients with a pre-operative history of bleeding (RH 3.3-5.1) and of atrial fibrillation (RH 1.8-3.9). The risk for a subsequent event was increased by a history of repeated haemorrhages, a short interval since previous bleeding, and high age. CONCLUSIONS There were few factors strongly related to valve related morbidity. However, previous bleedings and previous thromboembolism were powerful risk factors for repeated events.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis

Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...

متن کامل

Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm

Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...

متن کامل

Survival and long-term outcomes following bioprosthetic vs mechanical aortic valve replacement in patients aged 50 to 69 years.

IMPORTANCE The choice between bioprosthetic and mechanical aortic valve replacement in younger patients is controversial because long-term survival and major morbidity are poorly characterized. OBJECTIVE To quantify survival and major morbidity in patients aged 50 to 69 years undergoing aortic valve replacement. DESIGN, SETTING, AND PARTICIPANTS Retrospective cohort analysis of 4253 patient...

متن کامل

Ten year clinical evaluation of Starr-Edwards 2400 and 1260 aortic valve prostheses.

The long term performance characteristics of the 2400 and 1260 series of Starr-Edwards aortic prostheses were investigated by a follow up study of clinical outcome of 327 patients discharged from hospital with isolated aortic valve replacement. Follow up lasted for up to 10 years and was based on 1616 patient-years. The 2400 series cloth covered tracked valve was implanted in 182 patients from ...

متن کامل

Five-year follow-up after heart valve replacement with the CarboMedics bileaflet prosthesis.

BACKGROUND The CarboMedics valve is a relatively new, low-profile, bileaflet, mechanical prosthesis. The results of a prospective follow-up study after valve replacement with this prosthesis in a university hospital are presented. METHODS We implanted 640 CarboMedics prostheses in 583 patients in the aortic (n = 359), mitral (n = 167), or aortic and mitral positions (double valve replacement;...

متن کامل

AN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT

Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European heart journal

دوره 21 13  شماره 

صفحات  -

تاریخ انتشار 2000