Accuracy of formula preparation equipment for liquid measurement

نویسندگان

  • Sharon Evans
  • Catherine Ashmore
  • Anne Daly
  • Anita MacDonald
چکیده

BACKGROUND Modular specialist feeds may consist of a number of individual liquid ingredients. Accurate feed preparation is dependent on competent liquid measurement. We investigate the accuracy of two measuring jugs (one retail mix-and-measure; and one produced to laboratory standards); and the influence of volume and technique on accuracy. MATERIALS AND METHODS 20 health professionals aged 18-60 y (mean: 46 y) measured 3 different volumes of water with each of two measuring jugs. For each volume with each jug, 2 measurements in randomised order were made: 1) eye-level with the jug, and 2) standing upright (total of 12 measurements). Measured quantities were weighed and the difference between measured and target volumes calculated. RESULTS The laboratory jug was more accurate (mean difference 9.3 ml, range - 30.5 to 57.5 ml, std error mean 1.59) than the retail jug (mean difference - 17.7 ml, range - 92.0 to 48.5 ml, std error mean 1.59). Accuracy improved with increased volume (450 ml: mean difference - 9.4 ml, range - 75.5 to 49.5 ml, std error mean 1.95; and 810 ml: mean difference - 0.7 ml; range - 92.0 to 43.0 ml, std error mean 1.95). CONCLUSIONS Accurate measurement of liquid ingredients is difficult to achieve even for trained professionals. The cumulative effect of many different liquid measurement errors (inappropriate jug type, inaccurate volume measured and poor technique) may lead to clinically important errors in the preparation of modular specialist feeds.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بهینه سازی روش ریز استخراج مایع مایع پخشی برای تعیین مقادیر جزیی ملاتونین بزاقی بوسیله کروماتوگرافی مایع با عملکرد عالی

Background and aims: Due to low concentration of melatonin and also the existence of other compounds in body fluids, measuring the amount of melatonin is a serious challenge for the analysts. Before measurement of melatonin amounts using chromatographic method, sample preparation is unavoidable. The aim of current study is develop a new sample preparation method that not only have high accuracy...

متن کامل

A method for bubble volume measurement under constant flow conditions in gas–liquid two-phase flow

Measuring the volume of a bubble, especially at its detachment, is a basic subject in gas-liquid two-phase flow research. A new indirect method for this measurement under constant flow conditions is presented. An electronic device is designed and constructed based on laser beam intensity. This device calculates the frequency of the bubble formation by measuring the total time of the formation p...

متن کامل

The Effects of Excitation Signal on the Resolution of the Liquid Crystal Capacitive Chemical and Biological Sensors

In this paper excitation characteristics of the Liquid Crystal (LC) capacitive chemical and biological sensor are examined and the optimum frequency and voltage range for the sensor interface are introduced. Interdigitated capacitor has been used for the sensor capacitance measurement and two different molecular orientations, homeotropic and homogenous, have been considered. The LC sensor capac...

متن کامل

Sound Wave Propagation in Viscous Liquid-Filled Non-Rigid Carbon Nanotube with Finite Length

   In this paper, numerical results obtained and explained from an exact formula in relation to sound pressure load due to the presence of liquid inside the finite-length non-rigid carbon nanotubes (CNTs), which is coupled with the dynamic equations of motion for the CNT. To demonstrate the accuracy of this work, the obtained formula has been compared to what has been used by other research...

متن کامل

Proving Liquid Ultrasonic Flow Meters for Custody Transfer Measurement

Liquid ultrasonic flow meters (LUFMs) continue to gain popularity in petroleum measurement with the promise of high accuracy and low maintenance. These are favorable features, but because of the high volume and value of petroleum products, buyers and sellers must have a high level of confidence in the accuracy of measurement. This assurance in custody transfer measurement is gained by adherence...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2014