Completeness map evaluation demonstrated with candidate next-generation cardiac CT architectures.

نویسندگان

  • Baodong Liu
  • James Bennett
  • Ge Wang
  • Bruno De Man
  • Kai Zeng
  • Zhye Yin
  • Paul Fitzgerald
  • Hengyong Yu
چکیده

PURPOSE In this report, the authors introduce the general concept of the completeness map, as a means to evaluate the completeness of data acquired by a given CT system design (architecture and scan mode). They illustrate the utility of completeness map by applying the completeness map concept to a number of candidate CT system designs, as part of a study to advance the state-of-the-art in cardiac CT. METHODS In order to optimally reconstruct a point within a volume of interest (VOI), the Radon transform on all possible planes through that point should be measured. The authors quantified the extent to which this ideal condition is satisfied for the entire image volume. They first determined a Radon completeness number for each point in the VOI, as the percentage of possible planes that is actually measured. A completeness map is then defined as a 3D matrix of the completeness numbers for the entire VOI. The authors proposed algorithms to analyze the projection datasets in Radon space and compute the completeness number for a fixed point and apply these algorithms to various architectures and scan modes that they are evaluating. In this report, the authors consider four selected candidate architectures, operating with different scan modes, for a total of five system design alternatives. Each of these alternatives is evaluated using completeness map. RESULTS If the detector size and cone angle are large enough to cover the entire cardiac VOI, a single-source circular scan can have ≥99% completeness over the entire VOI. However, only the central z-slice can be exactly reconstructed, which corresponds to 100% completeness. For a typical single-source architecture, if the detector is limited to an axial dimension of 40 mm, a helical scan needs about five rotations to form an exact reconstruction region covering the cardiac VOI, while a triple-source helical scan only requires two rotations, leading to a 2.5x improvement in temporal resolution. If the source and detector of an inverse-geometry (IGCT) system have the same axial extent, and the spacing of source points in the axial and transaxial directions is sufficiently small, the IGCT can also form an exact reconstruction region for the cardiac VOI. If the VOI can be covered by the x-ray beam in any view, a composite-circling scan can generate an exact reconstruction region covering the VOI. CONCLUSIONS The completeness map evaluation provides useful information for selecting the next-generation cardiac CT system design. The proposed completeness map method provides a practical tool for analyzing complex scanning trajectories, where the theoretical image quality for some complex system designs is impossible to predict, without yet-undeveloped reconstruction algorithms.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Critical Design Evaluation of the Next Generation Space Protocol Architectures

In this paper, we first identify eight major design challenges imposed by the next generation space protocols design. Second, we further defined a design evaluation framework based on the space protocol design challenges. Third, we critically evaluate the design of seven leading protocols architectures presented in [RHC 05] [HCP 05] [Bergamo 05] [BCDFHSW 02] [BH 02] [Israel 02] [LB 06] using th...

متن کامل

A Reference Framework for Emergent Space Communication Architectures oriented on Galactic Geography

An exuberant space age is emergent, which is likely to see many compact yet innovative explorations much beyond imagined in the past requiring a reusable and sharable space communication infrastructure. Currently proposed space communication architectures mainly suffer from three design drawbacks high cost, narrowed scale and lack of concise geographical organization. Therefore, there has been ...

متن کامل

Evaluation of attenuation correction process in cardiac SPECT images

  Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...

متن کامل

[18F]FDG PET/CT in a case of recurrent primary cardiac osteosarcoma

Primary cardiac osteosarcoma is a very rare malignancy with a high incidence of local recurrence and systemic metastasis, contributing to the poor prognosis. Radiological modalities are commonly used for the evaluation of cardiac masses. 2-[18F]fluoro-2-deoxy-D-glucose ([18F]FDG) positron emission tomography/computed tomography is a valuable whole-body imaging modality in ...

متن کامل

Multirate hybrid CT/DT cascade ΣΔ modulators with decreasing OSR of back-end DT stages

This paper presents novel architectures of multirate hybrid cascade continuous-time/discrete-time !" modulators that take advantage of the potentially faster operation of the continuoustime part of the circuit, while keep a reduced sampling operation of the back-end discrete-time stages. Compared to conventional multirate !" modulators, the proposed architectures use a higher sampling rate in t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 39 5  شماره 

صفحات  -

تاریخ انتشار 2012