Reproducibility of wrist home blood pressure measurement with position sensor and automatic data storage

نویسندگان

  • Sakir Uen
  • Rolf Fimmers
  • Miriam Brieger
  • Georg Nickenig
  • Thomas Mengden
چکیده

BACKGROUND Wrist blood pressure (BP) devices have physiological limits with regards to accuracy, therefore they were not preferred for home BP monitoring. However some wrist devices have been successfully validated using established validation protocols. Therefore this study assessed the reproducibility of wrist home BP measurement with position sensor and automatic data storage. METHODS To compare the reproducibility of three different(BP) measurement methods: 1) office BP, 2) home BP (Omron wrist device HEM- 637 IT with position sensor), 3) 24-hour ambulatory BP(24-h ABPM) (ABPM-04, Meditech, Hun)conventional sphygmomanometric office BP was measured on study days 1 and 7, 24-h ABPM on study days 7 and 14 and home BP between study days 1 and 7 and between study days 8 and 14 in 69 hypertensive and 28 normotensive subjects. The correlation coefficient of each BP measurement method with echocardiographic left ventricular mass index was analyzed. The schedule of home readings was performed according to recently published European Society of Hypertension (ESH)- guidelines. RESULTS The reproducibility of home BP measurement analyzed by the standard deviation as well as the squared differences of mean individual differences between the respective BP measurements was significantly higher than the reproducibility of office BP (p < 0.001 for systolic and diastolic BP) and the reproducibility of 24-h ABPM (p < 0.001 systolic BP, p = 0.127 diastolic BP). The reproducibility of systolic and diastolic office versus 24-h ABPM was not significantly different (p = 0.80 systolic BP, p = 0.1 diastolic BP). The correlation coefficient of 24-h ABMP (r = 0.52) with left ventricular mass index was significantly higher than with office BP (r = 0.31). The difference between 24-h ABPM and home BP (r = 0.46) was not significant. CONCLUSION The short-term reproducibility of home BP measurement with the Omron HEM-637 IT wrist device was superior to the reproducibility of office BP and 24- h ABPM measurement. Furthermore, home BP with the wrist device showed similar correlations to targeted organ damage as recently reported for upper arm devices. Although wrist devices have to be used cautious and with defined limitations, the use of validated devices with position sensor according to recently recommended measurement schedules might have the potential to be used for therapy monitoring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Poor Reliability of Wrist Blood Pressure Self-Measurement at Home: A Population-Based Study.

The reliability of blood pressure measurement with wrist devices, which has not previously been assessed under real-life circumstances in general population, is dependent on correct positioning of the wrist device at heart level. We determined whether an error was present when blood pressure was self-measured at the wrist in 721 unselected subjects from the general population. After training, b...

متن کامل

Poor Reliability of Wrist Blood Pressure Self-Measurement at Home

ion (score) −0.80 (0.91) −2.58 to 0.97 0.4 −1.05 (0.60) −2.24 to 0.13 0.1 Digit span (score) 0.72 (1.89) −2.99 to 4.42 0.7 0.73 (1.26) −1.74 to 3.20 0.6 IPM (score) −0.48 (0.91) −2.27 to 1.31 0.6 0.11 (0.61) −1.08 to 1.31 0.9 Education, y 1.78 (1.19) −0.56 to 4.12 0.1 0.36 (0.80) −1.20 to 1.92 0.7 Multiple linear regression. Systolic and diastolic errors as dependent variable, respectively. Age...

متن کامل

Can validated wrist devices with position sensors replace arm devices for self-home blood pressure monitoring? A randomized crossover trial using ambulatory monitoring as reference.

BACKGROUND Electronic devices that measure blood pressure (BP) at the arm level are regarded as more accurate than wrist devices and are preferred for home BP (HBP) monitoring. Recently, wrist devices with position sensors have been successfully validated using established protocols. This study assessed whether HBP values measured with validated wrist devices are sufficiently reliable to be use...

متن کامل

تخمین بدون کاف فشارخون مبتنی بر ویژگی‌های زمانی سیگنال نبض

Blood pressure is one of the vital signs. Specially, it is crucial for some cases such as hypertension patients and it should be monitored continuously in ICU/CCU. It must be noted that current systems to measure blood pressure, often require trained operators. As an example, in post-hospital cares, blood pressure control is difficult except with the presence of a nurse or use of a device that ...

متن کامل

Measuring blood pressure at the wrist: more comfortable for patients and more convenient for doctors?

OBJECTIVES To compare the agreement between conventional measurement of blood pressure and measurements obtained using two automated devices; and to compare how comfortable each of the three methods of measurement were for patients. METHODS Blood pressure measurements and patient comfort scores were recorded using three different devices in 125-surgery and 40-community patients. The devices u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Cardiovascular Disorders

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2009