Distortionless Lossy Transmission Lines Terminated by in Series Connected RCL-Loads
نویسندگان
چکیده
The paper deals with a lossy transmission line terminated at both ends by non-linear RCL elements. The mixed problem for the hyperbolic system, describing the transmission line, to an initial value problem for a neutral equation is reduced. Sufficient conditions for the existence and uniqueness of periodic regimes are formulated. The proof is based on the finding out of suitable operator whose fixed point is a periodic solution of the neutral equation. The method has a good rate of convergence of the successive approximations even for high frequencies.
منابع مشابه
Application of Intelligent Water Drops in Transient Analysis of Single Conductor Overhead Lines Terminated to Grid-Grounded Arrester under Direct Lightning Strikes
In this paper, Intelligent water drop algorithm (IWD) is used to analyze single overhead line connected to grid-grounded arrester. In this approach, at first Norton’s equivalent circuit of the overhead line over lossy soil is computed by method of moments (MoM) and then for the problem under consideration, a nonlinear equivalent circuit in the frequency domain is proposed. Finally applying inte...
متن کاملHyperreal waves on transfinite, terminated, distortionless and lossless, transmission lines
A prior work examined the propagation of an electromagnetic wave on a transfinite transmission line—transfinite in the sense that infinitely many one-way infinite transmission lines are connected in cascade. That there are infinitely many such lines results in the wave propagating without ever reflecting at some discontinuity This work examines the case where the line is terminated after finite...
متن کاملVariability analysis of interconnect structures including general nonlinear elements in SPICE-type framework
Introduction: Over the past few decades, computer-aided simulation tools have become an important asset for the design, simulation and optimisation of complex electronic networks. Nonetheless, since large-scale integration and miniaturisation lead to an important impact of the manufacturing process on the system performance, appropriate instruments are needed to evaluate uncertainties of the ci...
متن کاملAnalysis of Time Response of Lossy Multiconductor Transmission Line Networks
Systems are considered consisting of an arbitrary number of multiconductor transmission lines joined and terminated by arbitrary linear networks. The fines are assumed to be Iossy, with frequency-dependent parameters. The system is analyzed in the frequency domain, and the inverse Fourier transform is used to obtain tbe time-domain response.
متن کاملEffects of CT and VT Connection Point on Distance Protection of Transmission Lines with FACTS Devices
This paper presents the effects of instrument transformers connection points on the measured impedance by distance relays in the presence of Flexible Alternating Current Transmission System (FACTS) devices with series connected branch. Distance relay tripping characteristic itself depends on the power system structural conditions, pre-fault operational conditions, and especially the ground ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circuits and Systems
دوره 2 شماره
صفحات -
تاریخ انتشار 2011