Three-Dimensional Finite Element Analysis of Anterior Single Implant-Supported Prostheses with Different Bone Anchorages

نویسندگان

  • Fellippo Ramos Verri
  • Joel Ferreira Santiago Júnior
  • Daniel Augusto de Faria Almeida
  • Ana Caroline Gonçales Verri
  • Victor Eduardo de Souza Batista
  • Cleidiel Aparecido Araujo Lemos
  • Pedro Yoshito Noritomi
  • Eduardo Piza Pellizzer
چکیده

The aim of this study was to evaluate the stress distribution of monocortical and bicortical implant placement of external hexagon connection in the anterior region of the maxilla by 3D finite element analysis (FEA). 3D models were simulated to represent a bone block of anterior region of the maxilla containing an implant (4.0 × 10.0 mm) and an implant-supported cemented metalloceramic crown of the central incisor. Different techniques were tested (monocortical, bicortical, and bicortical associated with nasal floor elevation). FEA was performed in FEMAP/NeiNastran software using loads of 178 N at 0°, 30°, and 60° in relation to implant long axis. The von Mises, maximum principal stress, and displacement maps were plotted for evaluation. Similar stress patterns were observed for all models. Oblique loads increased the stress concentration on fixation screws and in the cervical area of the implants and bone around them. Bicortical technique showed less movement tendency in the implant and its components. Cortical bone of apical region showed increase of stress concentration for bicortical techniques. Within the limitations of this study, oblique loading increased the stress concentrations for all techniques. Moreover, bicortical techniques showed the best biomechanical behavior compared with monocortical technique in the anterior maxillary area.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تعیین توزیع تنش استخوان اطراف ایمپلنت‌های فک پایین در طرح‎های مختلف پروتز به هنگام Mandibular- Flexure

Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...

متن کامل

مقایسه اثر مواد مختلف سازنده ساختار فلزی روکش بر توزیع تنش پیرامون ایمپلنت با آنالیز اجزاء محدود سه بعدی

Objectives: Despite the high success rate, implant-supported prostheses fail in some cases. Control of the applied forces is an important factor determining the success or failure of implants. Complete understanding of the biomechanical principles in implant-supported prostheses is necessary for offering an appropriate custom-made treatment plan for each patient and reducing the risk of functio...

متن کامل

Effect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis

Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...

متن کامل

Effect of Abutment Angulation and Material on Stress and Strain Distributions in Premaxillary Bone: A Three-Dimensional Finite Element Analysis

Background and Aim: Dental implants with angled abutments are often inserted in the anterior maxillary region due to the status of the residual ridge and aesthetic considerations. The purpose of this study was to assess stress and strain distributions in the premaxillary bone around dental implants by means of finite element analysis (FEA). Materials and Methods: Four three-dimensional (3D) fi...

متن کامل

مقایسه نسبت های مختلف طول تاج به طول ایمپلنت (Crown: Implant) در تنش های وارد به استخوان آلوئول به روش اجزای محدود

Preservation of bone-implant interface is vital for maintaining of implant treatment. There are some cases in which crown to fixture ratio is increased due to loss of residual ridge. In this condition knowledge of stresses acting over alveolar bone is important in regard to prognosis of treatment. In this study three different crown to fixture ratios evaluated under lateral forces considering s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015