Deep-ultraviolet cavity ringdown spectroscopy.

نویسندگان

  • M Sneep
  • S Hannemann
  • E J van Duijn
  • W Ubachs
چکیده

The sensitive optical detection technique of cavity ringdown spectroscopy is extended to the wavelength range 197-204 nm. A novel design narrowband Fourier-transform-limited laser is used, and the technique is applied to gas-phase extinction measurements in CO2, SF6, and O2. Further demonstration of the system capabilities is given in high-resolution recordings of the Schumann-Runge (0, 0), (1,0), and (2, 0) bands in O2.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A high-resolution spectrometer based on a compact planar two dimensional photonic crystal cavity array

Related Articles A Rayleigh-Brillouin scattering spectrometer for ultraviolet wavelengths Rev. Sci. Instrum. 83, 053112 (2012) Microcontroller based resonance tracking unit for time resolved continuous wave cavity-ringdown spectroscopy measurements Rev. Sci. Instrum. 83, 043110 (2012) Electronic properties of spiro compounds for organic electronics J. Chem. Phys. 136, 124702 (2012) Design and e...

متن کامل

Optical injection unlocking for cavity ringdown spectroscopy.

Continuous wave cavity ringdown spectroscopy requires a rapid termination of the injection of light into the cavity to initiate the decay (i.e., ringdown) event. We demonstrate a technique that accomplishes this through pulsed optical injection of a second laser into the main laser, resulting in 20-100 MHz frequency shifts in the otherwise cavity-locked main laser sufficient to create ringdown ...

متن کامل

Infrared Cavity Ringdown Spectroscopy of the Water Cluster Bending Vibrations

We report the first measurement of water monomer bending vibrations in gaseous (H2O)n clusters. Infrared cavity ringdown spectroscopy reveals discrete and sequentially blue-shifted bands near 6 μm for n ) 2-4 and unresolved broad features for n > 4, supporting both theoretical predictions and solid-state spectroscopy results. These measurements provide a measure of the monomer distortion that a...

متن کامل

Cavity Ringdown Laser Spectroscopy (CRDS):

Cavity Ringdown Spectroscopy has become a widely used technique in the optical absorption analysis of atoms, molecules, and optical components. The technique allows the determination of total optical losses within a closed cavity comprised of two or more mirrors, and can be made arbitrarily more sensitive by improvments in the cavity mirror reflectivity. Part of the great attraction that Cavity...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics letters

دوره 29 12  شماره 

صفحات  -

تاریخ انتشار 2004