Oculo-peritoneal shunt: draining aqueous humor to the peritoneum.

نویسندگان

  • Ana Maldonado-Junyent
  • Arturo Maldonado-Bas
  • Andrea Gonzalez
  • Francisco Pueyrredón
  • María Maldonado-Junyent
  • Arturo Maldonado-Junyent
  • Diego Rodriguez
  • Mariano Bulacio
چکیده

In 2010, there were estimated to be approximately 60.5 million people with glaucoma. This number is expected to increase to 79.6 million by 2020. In 2010, there were 8.4 million people with bilateral blindness caused by glaucoma, and this number is expected in increase to 11.2 million by 2020. Filtering implants are special devices that have been developed to reduce intraocular pressure in patients with refractory glaucoma. The success rate of these implants is relatively low, and they continue to fail over time. To avoid failure caused by the formation of scar tissue around the implants, attempts have been made to drain the aqueous humor to various sites, including the venous system, lacrimal sac, sinuses, and conjunctival fornix. Recently, a system to shunt aqueous humor from the anterior chamber to the peritoneum has been developed. The surgical technique involved in this system is a modification of the technique currently used by neurosurgeons for the treatment of hydrocephalus. We present the first case operated using this technique.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of peritoneal pseudocyst following ventriculo-peritoneal shunt by radionuclide method [Persian]

A 14 years old boy who had a ventriculo-peritoneal shunt since the age of 5 months, was hospitalized due to headaches, nausea, vomiting and abdominal distension. In abdominal CT and sonographic evaluation, pancreatic pseudocyst or mesentric cyst were suspected. Evaluation of the shunt by radionuclide, however, was diagnostic and revealed a pseudocyst at the peritoneal end of the shunt. Th...

متن کامل

Interference of Descemet's Membrane with Aqueous Humor Drainage via an ExPRESS Mini Shunt

PURPOSE To describe a case in which Descemet's membrane interfered with aqueous humor drainage through an ExPRESS mini shunt. This problem was successfully solved by Nd:YAG laser membranotomy. CASE REPORT A 70-year-old male, diagnosed with corticosteroid-induced glaucoma in his right eye, presented to our hospital. Topical betamethasone treatment was discontinued, and the patient was treated ...

متن کامل

Migration of a distal ventriculoperitoneal shunt catheter into the internal jugular vein and heart through the external jugular vein: case report.

A 6-year-old boy had undergone ventriculoperitoneal (VP) shunt for acute hydrocephalus because of a brain tumor at the age of 11 months, and presented with vomiting and somnolence after the shunt malfunctioned 6 days after VP shunt reconstruction, during which the right external jugular vein was injured during the tunneling process and the peritoneal catheter was not fixed to the peritoneum wit...

متن کامل

Laparoscopic assisted ventriculoperitoneal shunt revisions as an option for pediatric patients with previous intraabdominal complications Revisão de derivações ventrículo-peritoneais assistidas por videolaparoscopia como uma opção para pacientes pediátricos com complicações intra-abdominais

Multiple shunt failure is a challenge in pediatric neurosurgery practice and one of the most feared complications of hydrocephalus. Objective: To demonstrate that laparoscopic procedures for distal ventriculoperitoneal shunt failure may be an effective option for patients who underwent multiple revisions due to repetitive manipulation of the peritoneal cavity, abdominal pseudocyst, peritonitis ...

متن کامل

Alterations in the aqueous humor proteome in patients with a glaucoma shunt device

PURPOSE To investigate whether implantation of a glaucoma shunt device leads to inappropriate accumulation of plasma derived proteins in the aqueous humor. METHODS Aqueous humor samples were collected from 11 patients (study group) with a glaucoma shunt device undergoing either cataract surgery or a corneal transplant and 11 patients (control) with senile cataract undergoing routine cataract ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Arquivos brasileiros de oftalmologia

دوره 78 2  شماره 

صفحات  -

تاریخ انتشار 2015