Insertion site and sealing technique affect residual hearing and tissue formation after cochlear implantation.

نویسندگان

  • Alice Burghard
  • Thomas Lenarz
  • Andrej Kral
  • Gerrit Paasche
چکیده

Tissue formation around the electrode array of a cochlear implant has been suggested to influence preservation of residual hearing as well as electrical hearing performance of implanted subjects. Further, inhomogeneity in the electrical properties of the scala tympani shape the electrical field and affect current spread. Intracochlear trauma due to electrode insertion and the insertion site itself are commonly seen as triggers for the tissue formation. The present study investigates whether the insertion site, round window membrane (RWM) vs. cochleostomy (CS), or the sealing material, no seal vs. muscle graft vs. carboxylate cement, have an influence on the amount of fibrous tissue and/or new bone formation after CI implantation in the guinea pig. Hearing thresholds were determined by auditory brainstem response (ABR) measurements prior to implantation and after 28 days. The amount of tissue formation was quantified by evaluation of microscopic images obtained by a grinding/polishing procedure to keep the CI in place during histological processing. An insertion via the round window membrane resulted after 28 days in less tissue formation in the no seal and muscle seal condition compared to the cochleostomy approach. Between these two sealing techniques there was no difference. Sealing the cochlea with carboxylate cement resulted always in a strong new bone formation and almost total loss of residual hearing. The amount of tissue formation and the hearing loss correlated at 1-8 kHz. Consequently, the use of carboxylate cement as a sealing material in cochlear implantation should be avoided even in animal studies, whereas sealing the insertion site with a muscle graft did not induce an additional tissue growth compared to omitting a seal. For hearing preservation the round window approach should be used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan

Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...

متن کامل

Methods of Hearing Preservation during Cochlear Implantation

Introduction  Recent advances in surgical techniques and electrode design have made residual hearing preservation during cochlear implantation (CI) possible, achievable, and desirable. Objectives  The objective of this study was to review the literature regarding methods used for hearing preservation during CI surgery. Data Synthesis  We performed a search in the LILACS, MEDLINE, SciELO, PubMed...

متن کامل

Partial deafness cochlear implantation at the University of Kansas: techniques and outcomes.

BACKGROUND One of the most significant recent advances in cochlear implantation is the implantation of patients with residual hearing. These patients have a downsloping sensorineural hearing loss with poor speech discrimination and perform poorly with standard amplification. Studies using a variety of different electrode designs have demonstrated that it is possible to implant an inner ear and ...

متن کامل

The role of preoperative, intratympanic glucocorticoids for hearing preservation in cochlear implantation: a prospective clinical study.

BACKGROUND Hearing Preservation is becoming increasingly important in cochlear implantation as there is growing evidence that preserving the residual hearing, especially in the low frequencies in combination with the electric stimulation can significantly improve hearing and speech outcomes in noise. Besides the ongoing development of atraumatic implant electrodes and insertion techniques, the ...

متن کامل

Residual hearing preservation after cochlear implantation via round window or cochleostomy approach.

OBJECTIVES/HYPOTHESIS The purpose of the study was to investigate whether cochlear implantation using the round window approach provided better preservation of residual hearing than the cochleostomy approach. STUDY DESIGN Case-control study. METHODS We designed a case-control study including 40 patients from a tertiary referral center who underwent cochlear implantation surgeries using devi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hearing research

دوره 312  شماره 

صفحات  -

تاریخ انتشار 2014