Factors affecting eye drop instillation in glaucoma patients with visual field defect
نویسندگان
چکیده
BACKGROUND To investigate the success rate of eye drop instillation in glaucoma patients with visual field defect as well as non-glaucoma volunteers. Factors that may affect the success rate of eye drop instillation were also evaluated. DESIGN A prospective, observational study. PARTICIPANTS Seventy-eight glaucoma patients and 85 non-glaucoma volunteers were recruited in this study. METHODS Open angle glaucoma patients with visual field defect as well as non-glaucoma volunteers were asked to video record their procedures of eye drop instillation using a 5-mL plastic bottle of artificial tear solution. Success of eye drop instillation was judged on video based on the first one drop of solution successfully applied on the cornea, by two investigators. MAIN OUTCOME MEASURES Success rate of eye drop instillation in glaucoma patients and non-glaucoma volunteers. Factors related to success rate of eye drop instillation, such as visual field defect and clinical characteristics, were also analyzed using multivariable logistic regression. RESULTS No significant deference in mean age was observed between two groups (glaucoma: 64.5 ± 14.4 years, non-glaucoma: 60.9 ± 14.1 years, P = 0.1156). Success rate of eye drop instillation was significantly lower (P = 0.0215) in glaucoma patients (30/78; 38.5%) than in non-glaucoma volunteers (48/85; 56.5%). The most frequent reason of instillation failure in glaucoma patients was touching the bulbar conjunctiva, cornea, eyelid or eyelashes with the tip of the bottle (29.5%). Multivariable logistic regression analysis identified lower corrected visual acuity (VA) (≤ 1.0; odds ratio [OR] = 0.20, 95% confidence interval [CI] 0.04-0.93, P = 0.0411), lower mean deviation (MD) (< -12 dB; OR = 0.20, 95% CI 0.05-0.86, P = 0.0307) and visual field defect (VFD) in the inferior hemifield (OR = 0.11, 95% CI 0.02-0.34, P < 0.001) to be significantly related to instillation failure in glaucoma patients. CONCLUSIONS Success rate of eye drop instillation was significantly lower in glaucoma patients than in non-glaucoma volunteers. Corrected VA ≤ 1.0, MD < -12 dB and/or VFD in the inferior hemifield may be related to failure of eye drop instillation.
منابع مشابه
Review on the Eyedrop Self-Instillation Techniques and Factors Affecting These Techniques in Glaucoma Patients
Objective. This study aims to evaluate eyedrop self-installation techniques and factors affecting these techniques in glaucoma patients. Methods. Researchers directly observed eyedrop instillation procedures of 66 glaucoma patients. Contact with periocular tissues and instillation onto ocular surface or conjunctival fornices were considered. Correlations of instillation patterns with patient ch...
متن کاملVideographic Assessment of Glaucoma Drop Instillation
PURPOSE To assess the effect of patient education on videotaped topical instillation of artificial tear drops on subsequent topical instillation. MATERIALS AND METHODS Forty-five patients, who had been using glaucoma drops for at least 6 months and with a best-corrected visual acuity of 20/100 or better, were studied. The patients were asked to instill an artificial tear drop using their accu...
متن کاملManaging adverse effects of glaucoma medications
Glaucoma is a chronic, progressive disease in which retinal ganglion cells disappear and subsequent, gradual reductions in the visual field ensues. Glaucoma eye drops have hypotensive effects and like all other medications are associated with adverse effects. Adverse reactions may either result from the main agent or from preservatives used in the drug vehicle. The preservative benzalkonium chl...
متن کاملCompliance with Glaucoma Therapy with Eye Drops and its Determinants in Glaucoma Pa-tients Presenting to Clinics Affiliated to Shiraz University of Medical Sciences
Background: The present study was conducted to investigate medication compliance and its determinants in glaucoma patients presenting to Shahid Motahari Clinic affiliated to Shiraz University of Medical Sciences, Shiraz, Iran. The correlation between quality of life and the level of medication compliance was also evaluated in these patients. Materials and Methods: The present descriptive-analyt...
متن کاملEvaluation of the efficacy and safety of a new device for eye drops instillation in patients with glaucoma
OBJECTIVE This study evaluated the efficacy and safety of a new device (Eyedrop(®)) designed for eye drop instillation in patients with and without glaucoma. METHODS This prospective study included consecutive patients with glaucoma and healthy participants. After a complete eye examination and determination of baseline intraocular pressure (IOP), topical hypotensive medication was introduced...