Mapping choroidal and retinal thickness variation in type 2 diabetes using three-dimensional 1060-nm optical coherence tomography.

نویسندگان

  • Marieh Esmaeelpour
  • Boris Považay
  • Boris Hermann
  • Bernd Hofer
  • Vedran Kajic
  • Sarah L Hale
  • Rachel V North
  • Wolfgang Drexler
  • Nik J L Sheen
چکیده

PURPOSE To map choroidal (ChT) and retinal thickness (RT) in healthy subjects and patients with diabetes with and without maculopathy using three dimensional 1060-nm optical coherence tomography (3D-1060nm-OCT). METHODS Sixty-three eyes from 42 diabetic subjects (41-82 years of age; 11 females) grouped according to a custom scheme using Early Treatment Diabetic Retinopathy Study definitions for pathology within 1 disc-diameter of fovea (without pathology [NDR], microaneurysms [M1], exudates [M2], clinically significant macular edema [CSME]) and 16 eyes from 16 healthy age matched subjects (38-79 years of age; 11 females) were imaged by 3D-1060nm-OCT performed over a 36° × 36° field of view. Axial length, 45° fundus photographs, body mass index, plasma glucose, and blood pressure measurements were recorded. The ChT at the subfoveal location and ChT maps between RPE and the choroidal-scleral interface were generated and statistically analyzed. RESULTS RT maps show thinning in the NDR group but an increase in thickness with increasing maculopathy in the temporal and central regions (unpaired t-test; P < 0.05). ChT mapping of all diabetic patients revealed central and inferior thinning compared to healthy eyes (unpaired t-test; P < 0.001). Subfoveal ChT (mean ± SD) for healthy eyes was 327 ± 74 μm, which was significantly thicker than all diabetic groups (214 ± 55 μm for NDR, 208 ± 49 μm for M1, 205 ± 54 μm for M2, and 211 ± 76 μm for CSME (ANOVA P < 0.001; Tukey P < 0.001). CONCLUSIONS 3D-1060nm-OCT has shown that the central choroid is thinner in all type 2 diabetic eyes regardless of disease stage. The choroidal thinning may exceed the magnitude of possible choriocapillaris atrophy. In contrast to the conventional assessment of pathologic thickness change in several locations, thickness maps allow investigation of the choroid over the extent of affected areas.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mapping Retinal and Choroidal Thickness in Unilateral Nongranulomatous Acute Anterior Uveitis Using Three-Dimensional 1060-nm Optical Coherence Tomography.

Purpose To analyze retinal thickness (RT) and choroidal thickness (ChT) changes in patients with unilateral nongranulomatous acute anterior uveitis (AAU) using three-dimensional (3D) 1060-nm optical coherence tomography (OCT). Methods Retinal and choroidal thickness maps were statistically analyzed for 24 patients with newly diagnosed unilateral AAU before therapy. A total of 17 patients were...

متن کامل

Comparison of Choroidal Thickness in Psoriasis and Control Groups Using Optical Coherence Tomography

Background and Objective: One of the most common extracutaneous complications in psoriasis patients is ocular complications, which is controversial concerning its effect on choroidal thickness. This study aimed to compare the psoriasis patients with healthy individuals in terms of the thickness of the choroidal layer using the optical coherence tomography technique. Materials and Methods: In t...

متن کامل

Retinal and choroidal thickness in early age-related macular degeneration.

PURPOSE To compare retinal thickness and choroidal thickness at increasing retinal eccentricity in individuals with early age-related macular degeneration (AMD) and in healthy controls using enhanced choroidal penetration, 3-dimensional optical coherence tomography at 1060 nm. DESIGN Cross-sectional study. METHODS Individuals with early AMD (n = 16; mean age, 71.6 ± 8.5 years) and a compari...

متن کامل

In vivo human choroidal vascular pattern visualization using high-speed swept-source optical coherence tomography at 1060 nm.

PURPOSE To investigate the retinal and choroidal vascular pattern, structure, and thickness using high-speed, high axial resolution, swept-source optical coherence tomography (SS-OCT) at 1060 nm, demonstrating enhanced penetration through all choroidal layers. METHODS An ophthalmic SS-OCT system was developed operating at 57,000 A-lines/s with 5.9 μm axial resolution and was used to collect 3...

متن کامل

Differential phase-contrast, swept-source optical coherence tomography at 1060 nm for in vivo human retinal and choroidal vasculature visualization.

Human retinal and choroidal vasculature was visualized by a differential phase-contrast (DPC) method using high-speed, swept-source optical coherence tomography (SS-OCT) at 1060 nm. The vasculature was recognized as regions of motion by creating differential phase-variance (DPV) tomograms: multiple B-scans of individual slices through the retina were collected and the variance of the phase diff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 52 8  شماره 

صفحات  -

تاریخ انتشار 2011