Effects of specimen collection, processing, and storage conditions on stability of human immunodeficiency virus type 1 RNA levels in plasma.

نویسندگان

  • C C Ginocchio
  • X P Wang
  • M H Kaplan
  • G Mulligan
  • D Witt
  • J W Romano
  • M Cronin
  • R Carroll
چکیده

To define the optimal blood collection parameters for plasma human immunodeficiency virus type 1 (HIV-1) viral load testing, plasma HIV-1 RNA levels were quantitated with the NASBA HIV-1 RNA QT System from blood specimens that were collected, processed, and stored under a variety of conditions that might have affected HIV-1 RNA stability. We determined that when whole blood was processed within 2 h of specimen collection the levels of HIV-1 RNA detected in EDTA-, heparin-, and acid citrate dextrose (ACD)-anticoagulated plasma samples were comparable. The levels of HIV-1 RNA in serum specimens (mean = 4.126 log units) were significantly lower (P < 0.01) than the levels in corresponding plasma samples (mean = 4.501 log units). One cycle of freeze-thaw (-70 degrees C) did not significantly reduce the level of HIV-1 RNA detected in EDTA-, heparin-, or ACD-anticoagulated plasmas. The EDTA-anticoagulated plasmas showed the smallest decrease in HIV-1 RNA copies (0.050 log units). HIV-1 RNA levels decreased over a 6-month time period in serum as well as in EDTA-, ACD-, and heparin-anticoagulated plasmas stored at -70 degrees C. However, the only significant decreases were for serum (mean decrease = 0.317 log units) and heparin-anticoagulated samples (mean decrease = 0.384 log units). A comparison of the levels of HIV-1 RNA in cell-free plasma collected in VACUTAINER EDTA Plasma Preparation Tubes and in standard VACUTAINER EDTA tubes determined that HIV-1 RNA levels were stable for up to 30 h after collection when stored at either room temperature (mean standard deviation [SD] = +/- 0.101 log units) or at 4 degrees C (mean SD = +/- 0.102 log units) as cell-free plasma or as EDTA-anticoagulated whole blood (mean SD = +/- 0.109 log units). These data indicate that EDTA-anticoagulated plasma is the most suitable and stable matrix for HIV-1 RNA quantitation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of specimen-handling procedures for accurate quantitation of levels of human immunodeficiency virus RNA in plasma by reverse transcriptase PCR.

Human immunodeficiency virus type 1 (HIV-1) RNA levels in plasma are currently widely used clinically for prognostication and in monitoring antiretroviral therapy. Accurate and reproducible results are critical for patient management. To determine the effects of specimen collection and handling procedures on quantitative measurement of HIV-1 RNA, we compared anticoagulants and sample processing...

متن کامل

An Overview on Platelet-derived Microparticles in Platelet Concentrates: blood collection, method preparation and storage

Preparations of platelet concentrates (PCs) that are stored under blood bank conditions and used for transfusion purposes, appear to be enriched in platelet derived-microparticles (PMPs) with high coagulant activity that may change platelet efficacy and safety issues. High shear stress could cause shedding of PMPs from the platelet plasma membrane, platelet aggregation, and activation of the co...

متن کامل

Stability of human immunodeficiency virus RNA in blood specimens as measured by a commercial PCR-based assay.

We investigated the effects of conditions often encountered during handling, transit, and storage of blood specimens on the quantity of detectable human immunodeficiency virus (HIV) RNA in plasma. HIV RNA copy numbers were measured with a commercially available assay (the Amplicor HIV-1 Monitor test kit). Variables examined were the time to processing of blood and plasma, the holding temperatur...

متن کامل

Cytomegalovirus Active Infection in Persons Infected with Human Immunodeficiency Virus

Background and Objective: Cytomegalovirus (CMV), one of the most common opportunistic pathogens in patients infected with human immunodeficiency virus (HIV), can cause the diseases such as encephalitis, pneumonia, and chorioretinitis. This study aimed at molecular studying of CMV infection in individuals infected with the human immunodeficiency virus. Material and Methods: In this study, 50 ven...

متن کامل

Preanalytical stability of HIV-1 and HCV RNA: impact of storage and plasma separation from cells on blood donation testing by NAT.

BACKGROUND The aim of this study was to evaluate the optimal preanalytical conditions prior to nucleic acid amplification technology (NAT) for human immunodeficiency virus-1 (HIV-1) or Hepatitis C virus (HCV) RNA in pools of 96 plasma specimens with regard to storage temperature, time and plasma separation in a blood donation environment. STUDY DESIGN AND METHODS Changes in viral nucleic acid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 35 11  شماره 

صفحات  -

تاریخ انتشار 1997