A measurement of the diffuse reflectivity of 1056 Tyvek in air and water
نویسندگان
چکیده
The Pierre Auger Collaboration is constructing the first of two observatories designed to solve the mystery of the ultra high energy cosmic rays. Each observatory will consist of an array of 1600 water Cherenkov detectors spread on a surface of 3000km. The main part of these detectors is a polyethylene tank filled up with water and with three photomultipliers on the top. Tyvek will be used as the inner lining material of these Cherenkov detectors, because of its high reflectivity in the wavelengths of interest. Therefore, the optical properties of this material constitute an important element in the detection of cosmic rays. In this work, we report the results of our measurements of diffuse reflectivity of a sample of Tyvek, in air and water, as a function of the reflection angles for two different wavelengths: one at 488 nm (with an Argon laser) and another at 632.8 nm (using a Helium–Neon laser). We also show that there exist optical anisotropies of Tyvek which are revealed by the shape of its diffuse reflectivity curves when rotating the sample about its normal. r 2005 Elsevier B.V. All rights reserved. PACS: 78.68.+m; 29.40.Ka
منابع مشابه
Optimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement
Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...
متن کاملMeasurement Of Scatter Factors For Small Photon Fields Using Gaf chromic EBT2 Film
Introduction: Small field dosimetry is challenging for radiotherapy dosimetry. measurement of the output factor in the air and water (Sc, Scp) is one of the input parameters for commissioning of treatment planning systems and beam modeling. The aims of this study are to measured Sc,Scp for small fields with EBT2 and Ion chamber and design a appropriate mini-phantom for small fi...
متن کاملCalculating CR-39 Response to Radon in Water Using Monte Carlo Simulation
Introduction CR-39 detectors are widely used for Radon and progeny measurement in the air. In this paper, using the Monte Carlo simulation, the possibility of using the CR-39 for direct measurement of Radon and progeny in water is investigated. Materials and Methods Assuming the random position and angle of alpha particle emitted by Radon and progeny, alpha energy and angular spectrum that arri...
متن کاملDiffusion measurement in ferrous infused gel dosimeters
Background: The compositions of Ferrous sulphate, Agarose and Xylenol orange dye (FAX) and Ferrous sulphate, Gelatin and Xylenol orange dye (FGX) in solution of distilled water and sulphuric acid are two tissue-equivalent gel dosimeters. Ionizing radiation causes oxidation of Fe2+ ion to Fe3+ ions which diffuse through the gel matrix and blur the image of absorbed dose over a period of hours af...
متن کاملQualitative and quantitative study of water obtained from condensate atmosphere humidity in Bandar Abbas air conditioners
Introduction: Earth's atmosphere contains billion cubic meters of fresh water, which is considerable as a reliable water resource, especially insultry areas. What is important in this context, how to extract the water, in an economic manner. In order to extract water from air conditioner, no need to spend any cost, because water produced as a by-product and trouble production. The aim of study ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005