Clinical evaluation of locking compression plate fixation for comminuted olecranon fractures.

نویسندگان

  • Geert Buijze
  • Peter Kloen
چکیده

BACKGROUND In patients managed with plate fixation for the treatment of an olecranon fracture, the placement of an axial intramedullary screw may obstruct the placement of bicortical screws in the ulnar shaft. To overcome this problem, unicortical screws can be applied with use of a contoured locking compression plate. The present study was designed to assess the effectiveness of this fixation method. METHODS Nineteen consecutive patients with an acute comminuted olecranon fracture were managed with a contoured locking compression plate and intramedullary screw fixation. Sixteen patients were available for follow-up at a minimum of twelve months after fixation. Patient-based outcomes were assessed, and patient satisfaction and pain were evaluated. RESULTS All nineteen fractures healed. The mean time to fracture union was four months. The mean Disabilities of the Arm, Shoulder and Hand score was 13. According to the Mayo Elbow Performance Index and the Broberg and Morrey grading system, fifteen of the sixteen patients with at least one year of follow-up had a good or excellent outcome. Nine patients underwent hardware removal at a mean of twelve months postoperatively. The mean elbow extension deficit in these patients improved significantly from 34 degrees to 10 degrees following hardware removal. The mean flexion improved from 118 degrees to 138 degrees , but this difference was not significant. CONCLUSIONS In the treatment of comminuted olecranon fractures, a contoured locking compression plate combined with an intramedullary screw provides sufficient stability for early postoperative functional rehabilitation, with an excellent fracture union rate and very good clinical outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of type 2 and 4 olecranon fractures with locking compression plate osteosynthesis in horses: a prospective study (2002-2008).

This prospective study describes a series of 18 olecranon fractures in 16 horses that were treated with locking compression plates (LCP). Twelve of the 18 fractures were simple (type 2), whereas six were comminuted (type 4). Six fractures were open and 12 were closed. Each horse underwent LCP osteosynthesis consisting of open reduction and application of one or two LCP. Complete fracture healin...

متن کامل

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

Comparison of tension band wiring and precontoured locking compression plate fixation in Mayo type IIA olecranon fractures.

Aim of the present study was to compare the clinical and radiographic outcome of tension band wiring and precontoured locking compression plate fixation in patients treated surgically for an isolated olecranon fractures type IIA according to the Mayo classification. Of 26 patients presenting with an isolated Mayo type IIA olecranon fracture, 13 underwent fixation with a precontoured locking com...

متن کامل

Operative treatment of communited olecranon fractures using tension-band wiring and miniplate augmentation.

Olecranon fractures are intra-articular injuries that require anatomic restoration of the articular surface. For most simple noncomminuted transverse olecranon fractures, tension band wire fixation can provide a stable construct to allow for early joint range of motion. However, in comminuted olecranon fractures, it is difficult to provide a sufficient buttress for impacted articular fragments ...

متن کامل

Results of open reduction and plate osteosynthesis in comminuted fracture of the olecranon.

HYPOTHESIS Using radiologic and clinical results, we studied the outcome of patients who underwent open reduction and plate osteosynthesis for comminuted olecranon fractures. MATERIALS AND METHODS We retrospectively studied 18 patients (5 women [27.8%] and 13 men [72.2%]; mean age, 41 years [range, 19-67 years]) with comminuted fractures of the olecranon who underwent locking-plate osteosynth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 91 10  شماره 

صفحات  -

تاریخ انتشار 2009