In vitro variability in fentanyl absorption by different membrane oxygenators.
نویسندگان
چکیده
The membrane oxygenator has replaced the bubble oxygenator in a wide variety of clinical settings. The membrane oxygenators now manufactured can be grouped into three categories based on composition and design: (1) silicone with a true membrane structure; (2) polypropylene with a microporous sheet; and (3) polypropylene with a microtubular structure. The capacity for fentanyl uptake by membrane oxygenators from these three categories was studied in vitro. Representative membrane samples were incubated in solutions containing tritiated fentanyl in Normosol-R (Abbott, North Chicago, IL) with pH adjusted to 7.4 at 37 degrees C. Fentanyl analysis was performed using liquid scintillation and radioimmunoassay techniques. The uptake of fentanyl at various concentrations (340 to 10 ng/mL) was studied. The SciMed (type 1; SciMed, Minneapolis, MN) membrane showed the greatest capacity for fentanyl uptake at all concentrations. The SciMed oxygenator was capable of binding 130 ng fentanyl/cm2 membrane. When presented with a smaller concentration (less than or equal to 20 ng/mL) of fentanyl, the membrane was able to extract all available fentanyl from solution. All of the microporous polypropylene oxygenators (types 2 and 3) absorbed significantly less fentanyl than did the SciMed brand. When exposed to 10 or 20 ng/mL, the Shiley and Omnis brands (type 2) absorbed 0.1 and 0.4 ng/cm2, respectively. Using the higher fentanyl concentrations (greater than or equal to 200 ng/mL) uptake by the Omnis membrane was 11 ng/cm2 compared with only 2 ng/cm2 by the Shiley. The Bentley BCM 7 and Terumo Capiox II 08 microtubular microporous membranes (type 3) did not show absorption of fentanyl using isolated or intact membrane models.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Gaseous microemboli and the influence of microporous membrane oxygenators.
Gaseous microemboli (GME) are still an unsolved problem of extracorporeal circuits. They are associated with organ injury during cardiopulmonary bypass. Microbubbles of different sizes and number are generated in the blood as the result of different components of the extracorporeal circuit as well as surgical maneuvers. The aim of our study was to observe the behavior of microporous membrane ox...
متن کاملIn vitro drug adsorption and plasma free hemoglobin levels associated with hollow fiber oxygenators in the extracorporeal life support (ECLS) circuit.
The purpose of this study was to identify the percentage of fentanyl or morphine sulfate lost from adhesion to either the polyvinylchloride (PVC) tubing or the surface of two different hollow fiber oxygenators used in current extracorporeal life support circuits and to identify any difference in the plasma free hemoglobin (PFH) levels generated when using these oxygenator and/or drug combinatio...
متن کاملFentanyl uptake by the scimed membrane oxygenator.
With the initiation of cardiopulmonary bypass (CPB), using a membrane oxygenator, the drop in circulating fentanyl concentration is greater than can be attributed to dilution alone. This study examined the Scimed brand (2A-800) membrane oxygenator as a site of fentanyl binding. Initial experiments used an assembled CPB circuit. Subsequent dissection and analysis of the oxygenator revealed that ...
متن کاملIn vitro and in vivo evaluation of a new sublingual tablet system for rapid oromucosal absorption using fentanyl citrate as the active substance.
Oromucosal delivery of drugs promotes rapid absorption and high bioavailability, with subsequent almost immediate onset of pharmacological effect. However, many oromucosal delivery systems are compromised by the possibility of the patient swallowing the active substance before it has been released and absorbed locally into the systemic circulation. This paper introduces a new tablet system for ...
متن کاملAn in vitro protocol for evaluation and comparison of membrane oxygenators.
With the trend in open heart surgery toward normothermic bypass and warm blood cardioplegia, greater demand is being placed on the perfusionist to select an oxygenator that will perform safely and efficiently under a variety of conditions. While manufacturers report performance parameters for their products, the data is often not comparable due to widely differing conditions. Recent in vitro ...