Comparison of reproducibility between continuous, pulsed, and pseudo-continuous arterial spin labeling

نویسندگان

  • Y. Chen
  • J. Wang
  • M. Korczykowski
  • M. Fernandez-Seara
  • J. A. Detre
چکیده

Introduction Arterial spin labeling (ASL) is a noninvasive method for measuring cerebral blood flow (CBF). There are two broad categories of ASL: continuous (CASL), which uses a long train of square pulses to approximate a continuous inversion of flowing spins; and pulsed (PASL), which uses a short inversion pulse to label a fixed amount of blood. Theoretically, CASL has higher signal-to-noise ratio than PASL, but it is limited to transmit/receive coils due to the high radiofrequency duty cycle. Recently, a modification of CASL called pseudo-continuous ASL (pCASL) was introduced . pCASL combines the SNR advantage of CASL and the lower power deposition of PASL, which makes it possible to use the more sensitive array coils. While initial assessments appear optimistic, there has been no formal comparison of the reproducibility of the various methods including both within and across session measures, which estimate both instrumental and physiological noises. In this study, we investigate the reproducibility of three variants of ASL: CASL, PASL and pCASL. Methods Data from twelve healthy subjects (7F, mean age 24) scanned at rest were collected on a 3T whole-body scanner (Siemens Trio, Erlangen, Germany) with both an 8-channel receive-only coil and a transmit/receive head coil (for CASL). Sequence parameters for the different sequences are as follows: 1) PASL (FAIR) – TIs=700/1700ms, 40 pairs, 2) pCASL – PLD=1s, τ=1.5s, label offset=80mm, 40 pairs, 3) CASL – PLD = 1s, τ=2s, label offset=80mm, 40 pairs. All data were collected using gradient-echo EPI (TR/TE=4s/17ms, 14 x 6mm slices, 3.75 in-plane resolution). Scans were repeated within-session, after 1 hour and after 1 week. CASL was performed only on a subset of 7 subjects. Other scans include a high-resolution T1-MPRAGE, used for coregistration and normalization, as well as an M0 image for quantification of PASL data. Perfusion images calculated from pair-wise subtractions between control and tag images were converted to quantitative CBF maps using pre-established models. Whole-brain gray and white matter segmentation masks were used to generate the CBF data used for calculating repeatability and within-subject coefficients of variation (wsCV), which were compared between the different sessions. Results & Discussion Correlation plots for gray matter (GM) CBF between scan 1 and the subsequent scans for all three sequences are shown to the left. Line of unity is shown to guide the eye. While excellent correlation is seen within session, the 1 hr and 1wk correlations were visibly worse. A summary of the results, including the mean CBF, repeatability in ml/100g/min and wsCV in % are shown in the table below. Raw and temporal signal-to-noise ratios (SNR), normalized to PASL, are also shown in the table. While both pCASL and CASL have similar wsCV within-session, pCASL outperforms CASL at the 1hour and 1week scan. Another advantage of pCASL is that it can be implemented with the more sensitive array coil, evident in the high raw SNR of pCASL compared to CASL (paired t-test, p<0.001). The transmit/receive coil may also account for the poor reproducilibity of CASL after 1hr and 1wk, as different positioning of the subjects could result in variability in labeling efficiency, which in turn affects the CBF estimates. Relative to PASL, pCASL has superb wsCV and repeatability within-session (~50% less variability), however, the two methods have similar degrees of wsCV for the 1week scan. It is important to note that pCASL has a significant SNR advantage over PASL (~60% gain in raw SNR, paired t-test, p<0.001 and 20% gain in temporal SNR, paired t-test, p=0.02), likely due to the intrinsic signal advantage of CASL methods. Repeatability in gray matter show a similar trend as the wsCVs, however, better repeatability at the 1wk scan was observed in WM for the CASL-based methods, potentially due to the better labeling efficiency of CASL compared to PASL. Conclusion Our results show that pCASL and PASL have the lowest wsCVs of ~13% for scans performed 1wk apart. Additionally, pCASL has higher tSNR and is not limited to transmit/receive coils as traditional CASL. These advantages make pCASL a favorable method for measuring CBF.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intra- and multicenter reproducibility of pulsed, continuous and pseudo-continuous arterial spin labeling methods for measuring cerebral perfusion.

Intra- and multicenter reproducibility of currently used arterial spin labeling (ASL) methods were assessed at three imaging centers in the Netherlands, equipped with Philips 3TMR scanners. Six healthy participants were scanned twice at each site. The imaging protocol consisted of continuous ASL (CASL), pseudo-continuous ASL (p-CASL) with and without background suppression, pulsed ASL (PASL) wi...

متن کامل

Multicenter Reproducibility of Continuous, Pulsed and Pseudo-Continuous Arterial Spin Labeling; Can we use General Reference Values of Cerebral Blood Flow?

Introduction Cerebral perfusion imaging plays an important role in the evaluation of brain disease. Arterial spin labeling (ASL) is a relatively new and non-invasive perfusion imaging technique that uses magnetically labeled arterial blood water protons as an endogenous tracer of flow. Its non-invasiveness makes ASL an attractive tool compared to standard clinical methods. However, low SNR and ...

متن کامل

A theoretical and experimental comparison of continuous and pulsed arterial spin labeling techniques for quantitative perfusion imaging.

Under ideal conditions, continuous arterial spin labeling (ASL) techniques are higher in SNR than pulsed ASL techniques by a factor of e. Presented here is a direct theoretical and experimental comparison of continuous ASL and pulsed ASL, using versions of both that are amenable to multislice imaging and insensitive to variations in transit times (continuous ASL with a delay before imaging, and...

متن کامل

Inter-Vendor Reproducibility of Pseudo-Continuous Arterial Spin Labeling at 3 Tesla

PURPOSE Prior to the implementation of arterial spin labeling (ASL) in clinical multi-center studies, it is important to establish its status quo inter-vendor reproducibility. This study evaluates and compares the intra- and inter-vendor reproducibility of pseudo-continuous ASL (pCASL) as clinically implemented by GE and Philips. MATERIAL AND METHODS 22 healthy volunteers were scanned twice o...

متن کامل

Practical Investigation of pseudo-Continuous Arterial Spin Labeling (pCASL) feasibility at very high field (11.75T)

Introduction: A new strategy for continuous arterial spin labeling (CASL) using pulsed RF and gradient fields and referred as pseudo-continuous ASL (pCASL), has recently been developed and optimized for human studies at 3T. Promising results demonstrated that pCASL combines advantages of pulsed ASL (PASL) and CASL by providing good labeling efficiency, high Signal to Noise (SNR) and multi-slice...

متن کامل

Quantitative Functional Arterial Spin Labeling (fASL) MRI – Sensitivity and Reproducibility of Regional CBF Changes Using Pseudo-Continuous ASL Product Sequences

Arterial spin labeling (ASL) magnetic resonance imaging is increasingly used to quantify task-related brain activation. This study assessed functional ASL (fASL) using pseudo-continuous ASL (pCASL) product sequences from two vendors. By scanning healthy participants twice with each sequence while they performed a motor task, this study assessed functional ASL for 1) its sensitivity to detect ta...

متن کامل