Responses to chromatic and luminance contrast in glaucoma: a psychophysical and electrophysiological study
نویسندگان
چکیده
Increasing anatomical evidence indicates that large retinal ganglion cells (M-cells) are preferentially damaged in primary open angle glaucoma (OAG), while the smaller ganglion cells (P-cells) are relatively spared. In 13 patients with defined OAG and modest visual field defects, we evaluated the responses to stimuli that are expected to involve primarily the function of the P-pathway and compared them with those of control subjects. The psychophysical contrast sensitivity (CS), the PERG and the VEPs were measured for red-green gratings of pure chromatic contrast, as well as yellow-black gratings of pure luminance contrast. As compared with controls, OAG patients had reduced CS for both luminance and chromatic contrast stimuli by about 6 dB. PERGs and VEPs to luminance stimuli were little affected, whereas those to chromatic stimuli were both reduced in amplitude and delayed. These results indicate that visual dysfunction in glaucoma is not selective for the M-pathway, and that responses to equiluminant colour-contrast stimuli may be of diagnostic value.
منابع مشابه
Visual evoked potential assessment of the effects of glaucoma on visual subsystems
The purpose of this study is to test the hypothesis that glaucoma leads to selective deficits in parallel pathways or channels. Sweep VEPs were obtained to isolated-check stimuli that were modulated sinusoidally in either isoluminant chromatic contrast or in positive and negative luminance contrast. Response functions were obtained from 14 control subjects, 15 patients with open-angle glaucoma,...
متن کاملA Glance at Psychophysics Software Programs
Visual stimulation with precise control of stimulus has transformed the field of psychophysics since the introduction of personal computers. Luminance and chromatic features of stimulus, timing, and position of the stimulus are the main features that could be defined using programs written specifically for psychophysical experiments. In this manuscript, software used for the psychophysical expe...
متن کاملPsychophysical and physiological responses to gratings with luminance and chromatic components of different spatial frequencies.
Gratings that contain luminance and chromatic components of different spatial frequencies were used to study the segregation of signals in luminance and chromatic pathways. Psychophysical detection and discrimination thresholds to these compound gratings, with luminance and chromatic components of the one either half or double the spatial frequency of the other, were measured in human observers...
متن کاملMagnetic and electrical brain responses to chromatic contrast in human
Differences between magnetic responses to red-green chromatic gratings and yellow-black luminance gratings were: (1) response waveforms differed considerably; (2) at some recording sites the chromatic grating response was considerably greater than the sum of responses to the red and green components of the chromatic grating; (3) the latencies of the successive peaks in the response to the onset...
متن کاملThe use of chromatic information for motion segmentation: differences between psychophysical and eye-movement measures.
Previous psychophysical studies have shown that chromatic (red/green) information can be used as a segmentation cue for motion integration. We investigated the mechanisms mediating this phenomenon by comparing chromatic effects (and, for comparison, luminance effects) on motion integration between two measures: (i) directional eye movements with the notion that these responses are mediated main...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Vision Research
دوره 37 شماره
صفحات -
تاریخ انتشار 1997