Dual-Energy Contrast-Enhanced Spectral Mammography: Enhancement Analysis on BI-RADS 4 Non-Mass Microcalcifications in Screened Women

نویسندگان

  • Yun-Chung Cheung
  • Yu-Hsiang Juan
  • Yu-Ching Lin
  • Yung-Feng Lo
  • Hsiu-Pei Tsai
  • Shir-Hwa Ueng
  • Shin-Cheh Chen
چکیده

BACKGROUND Mammography screening is a cost-efficient modality with high sensitivity for detecting impalpable cancer with microcalcifications, and results in reduced mortality rates. However, the probability of finding microcalcifications without associated cancerous masses varies. We retrospectively evaluated the diagnosis and cancer probability of the non-mass screened microcalcifications by dual-energy contrast-enhanced spectral mammography (DE-CESM). PATIENTS AND METHODS With ethical approval from our hospital, we enrolled the cases of DE-CESM for analysis under the following inclusion criteria: (1) referrals due to screened BI-RADS 4 microcalcifications; (2) having DE-CESM prior to stereotactic biopsy; (3) no associated mass found by sonography and physical examination; and (4) pathology-based diagnosis using stereotactic vacuum-assisted breast biopsy. We analyzed the added value of post-contrast enhancement on DE-CESM. RESULTS A total of 94 biopsed lesions were available for analysis in our 87 women, yielding 27 cancers [19 ductal carcinoma in situ (DCIS), and 8 invasive ductal carcinoma (IDC)], 32 pre-malignant and 35 benign lesions. Of these 94 lesions, 33 showed associated enhancement in DE-CESM while the other 61 did not. All 8 IDC (100%) and 16 of 19 DCIS (84.21%) showed enhancement, but the other 3 DCIS (15.79%) did not. Overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 88.89%, 86.56%, 72.72%, 95.08% and 87.24%, respectively. The performances of DE-CESM on both amorphous and pleomorphic microcalcifications were satisfactory (AUC 0.8 and 0.92, respectively). The pleomorphous microcalcifications with enhancement showed higher positive predictive value (90.00% vs 46.15%, p = 0.013) and higher cancer probability than the amorphous microcalcifications (46.3% VS 15.1%). The Odds Ratio was 4.85 (95% CI: 1.84-12.82). CONCLUSION DE-CESM might provide added value in assessing the non-mass screened breast microcalcification, with enhancement favorable to the diagnosis of cancers or lack of enhancement virtually diagnostic for non-malignant lesions or noninvasive subgroup cancers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Role of Dynamic Contrast-Enhanced MR Imaging for Patients with BI-RADS 3–4 Microcalcifications

OBJECTIVE The purpose of study was to prospectively evaluate the diagnostic performance of dynamic contrast-enhanced MR imaging in the differentiation of malignant lesions from benign ones in patients with BI-RADS 3-4 microcalcifications detected by mammography. MATERIALS AND METHODS 93 women with 100 microcalcifications had undergone breast MRI from June 2010 to July 2013. Subsequently, 91 r...

متن کامل

A Comparative Study of the Diagnostic Value of Contrast-Enhanced Breast MR Imaging and Mammography on Patients with BI-RADS 3–5 Microcalcifications

OBJECTIVE To retrospectively investigate the diagnostic value of breast MRI in patients with BI-RADS 3-5 microcalcifications in mammography. METHODS Eighty-four patients with BI-RADS 3-5 microcalcifications on mammography underwent breast MR exams before surgical biopsy with a hookwire position under mammographic guidance. Two radiologists reviewed each lesion with BI-RADS by consensus. The d...

متن کامل

MRI for the assessment of malignancy in BI-RADS 4 mammographic microcalcifications

PURPOSE Assess the performance of breast MRI to diagnose breast cancer in BI-RADS 4 microcalcifications detected by mammography. MATERIALS AND METHODS This retrospective, IRB-approved study included 248 consecutive contrast-enhanced breast MRI (1.5T, protocol in accordance with EUSOBI recommendations) performed to further diagnose BI-RADS 4 microcalcifications detected at mammography during a...

متن کامل

The value of dynamic contrast enhanced breast MRI in mammographically detected BI-RADS 5 microcalcifications.

AIMS To evaluate the role of dynamic contrast-enhanced magnetic resonance imaging (MRI) in the diagnosis of BI-RADS-5 type of microcalcifications of the breast, to compare the size of the microcalcification lesions using mammography (MG) and MRI, and to determine the value of MRI in surgery for microcalcifications. The study also determines the morphology of microcalcification lesions, assesses...

متن کامل

Mammographic features and correlation with biopsy findings using 11-gauge stereotactic vacuum-assisted breast biopsy (SVABB).

BACKGROUND Mammograms are assigned a BI-RADS (Breast Imaging Reporting and Data System) category, which indicates the level of suspicion for cancer. OBJECTIVES (i) To evaluate the use of BI-RADS categories in a non-academic radiology practice based in a community hospital compared with local radiology private offices; (ii) to determine positive predictive value (PPV), sensitivity and specific...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016