Identification of heart disease-prone personality using oscillometric blood pressure measurements.

نویسندگان

  • Seungah Jung
  • Youngsuk Shin
چکیده

BACKGROUND By using the conventional method of measuring two-points (systolic and diastolic) blood pressure, it is difficult to differentiate a heart disease-prone personality from normals. Recently, an oscillometric method that reflects the personalized trait of blood pressure was developed by one author. OBJECTIVE By using this new measurement technique, this study intended to test the possibility of differentiating a heart disease-prone personality (type A or type D) from normal people. METHODS TPA scale in MMPI-2 and DS14 were used for screening type A and D. Oscillometric waveforms created by the cuff pressure were segmented into window blocks based on a single beat at a minimum, allowing this method to extract maximal top and bottom amplitudes in each window block. Then, a spectrogram using a short-time Fourier transform was applied to discriminate between character types in extracted blood pressure patterns with linear discriminant analysis. RESULTS Compared to a normal personality, type A and type D personalities displayed a lower frequency response on STFT with maximum negative amplitudes than normals. In particular, the type D personality showed a lower frequency response than the type A personality. CONCLUSION These results could provide a new qualitative method for measuring different biological indices between type A or D personalities and normals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring Personalized Trait Using Oscillometric Arterial Blood Pressure Measurements

The blood pressure patterns obtained from a linearly or stepwise deflating cuff exhibit personalized traits, such as fairly uniform peak patterns and regular beat geometry; it can support the diagnosis and monitoring of hypertensive patients with reduced sensitivity to fluctuations in Blood Pressure BP over time. Monitoring of personalized trait in Oscillometric Arterial Blood Pressure Measurem...

متن کامل

A clinical evaluation of blood pressure through non-invasive measurement using the oscillometric procedure in conscious dogs.

The oscillometric procedure was used to measure the heart rate as well as the systolic, mean, and diastolic blood pressures of 152 dogs (102 in the control group, 13 in the group with renal disease, 37 in the group with heart disease) who were brought to Azabu University of Veterinary Teaching Hospital. It was demonstrated that the blood pressure and heart rate of the control group lowered and ...

متن کامل

Impact of atrial fibrillation on the accuracy of oscillometric blood pressure monitoring.

The introduction of automated oscillometric blood pressure monitors was the basis for today's widespread use of blood pressure self-measurement. However, in atrial fibrillation, there is a controversial debate on the use of oscillometry because there is a high variability of heart rate and stroke volume. To date, the accuracy of oscillometric blood pressure monitoring in atrial fibrillation has...

متن کامل

Rapid oscillometric blood pressure measurement compared to conventional oscillometric measurement.

BACKGROUND There have been few reports studying the necessary interval between blood pressure measurements, after the initial rest period. METHODS Blood pressure was measured in 50 patients using the conventional oscillometric technique (COT) and the rapid oscillometric technique (ROT). RESULTS The difference between COT and ROT was -1.1 / -0.1 mmHg, which was not significantly different (p...

متن کامل

Comparison of aneroid and oscillometric blood pressure measurements in children.

Limited data exist on the comparison of blood pressure (BP) measurements using aneroid and oscillometric devices. The purpose of the study was to investigate the difference in BP obtained using oscillometric and aneroid BP monitors in 9- to 10-year-old children. A total of 979 children were divided into group O, which underwent two oscillometric BP readings followed by two aneroid readings, and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Technology and health care : official journal of the European Society for Engineering and Medicine

دوره 23 Suppl 2  شماره 

صفحات  -

تاریخ انتشار 2015