Evaluation of cation-exchange HPLC compared with isoelectric focusing for neonatal hemoglobinopathy screening.

نویسندگان

  • M Campbell
  • J S Henthorn
  • S C Davies
چکیده

BACKGROUND Central Middlesex Hospital, in northwest London, has screened neonates for hemoglobinopathies, using the established manual technique of isoelectric focusing (IEF) since 1989. Recently, this laboratory has faced a large increase in the number of samples tested per year. This study compared the detection of hemoglobin abnormalities between the existing manual IEF method and that of automated cation-exchange HPLC to determine the reliability of HPLC and whether an automated system would save time in the laboratory. METHODS Over a 15-month period, 25 750 blood samples, collected by heel prick onto filter paper, were tested using HPLC, and the results were compared with those obtained with IEF. RESULTS HPLC and IEF each identified 568 patients with FAS, 151 with FAC, 49 with FAD-Punjab, 23 with FS, 3 with FC, 6 with FSC, 5 with FE, and 1 with FD. IEF detected 62 patients with FAE, whereas HPLC detected 63. This additional FAE was observed on repeat IEF. One additional heterozygote detected by HPLC was initially not observed by IEF, but was detected on repeat IEF. HPLC detected all but six cases of Hb Barts observed by IEF. One double heterozygote and four heterozygotes were detected by IEF, but not by HPLC. The detection of hemoglobin variants expressed at low concentrations was comparable for the two methods, and carryover was not observed in routine analysis on HPLC. CONCLUSIONS HPLC is a sensitive, efficient, and time-saving alternative to IEF for the neonatal screening of common hemoglobinopathies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Newborn screening for sickle cell disease using tandem mass spectrometry.

BACKGROUND Neonatal screening programs for sickle cell disease are now widespread in North American and European countries. Most programs apply isoelectric focusing or HPLC to detect hemoglobin variants. Because tandem mass spectrometry (MS/MS) is being used for screening of inherited metabolic disorders and allows protein identification, it was worth testing for hemoglobinopathy screening. M...

متن کامل

Capillary isoelectric focusing and high-performance cation-exchange chromatography compared for qualitative and quantitative analysis of hemoglobin variants.

We have developed two assays for complete analysis of hemoglobins (Hbs) in the field of hemoglobinopathies: a high-performance cation-exchange liquid chromatography (HPLC) assay on the weak cation-exchanger Poly Cat A and a two-step capillary isoelectric focusing (CIEF) assay on the neutral-coated capillary from Beckman in a narrow pH gradient. The resolution was satisfactory for both HPLC and ...

متن کامل

Diagnostic utility of isoelectric focusing and high performance liquid chromatography in neonatal cord blood screening for thalassemia and non-sickling hemoglobinopathies.

BACKGROUND Thalassemia syndromes are highly prevalent in Southeast Asia. In Thailand, high performance liquid chromatography (HPLC) is the most common technique routinely performed in diagnosis of thalassemia and hemoglobinopathies, while isoelectric focusing (IEF) is rarely employed. We compared the diagnostic utility of IEF and HPLC in neonatal screening for thalassemia and non-sickling hemog...

متن کامل

Identification of human hemoglobins by use of isoelectric focusing in gel.

Newly-developed gel isoelectric focusing techniques provide for rapid and correct identification of human hemoblobins. With this technique, we examined samples previously identified by the National Hemoglobinopathy Standardization Laboratory of the Center for Disease Control. A wide variety of both normal and abnormal hemoglobins was included in the 134 different specimens examined. The isoelec...

متن کامل

[Prevalence of hemoglobin S in the State of Paraná, Brazil, based on neonatal screening].

The Brazilian Ministry of Health created the National Neonatal Screening Program under ruling no. 822/2001, including neonatal screening for hemoglobinopathies. In the State of Paraná, neonatal screening is conducted by the Ecumenical Foundation for the Protection of the Handicapped. The prevalence rates were determined for homozygous and heterozygous hemoglobin S and Sbeta-thalassemia. Blood s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 45 7  شماره 

صفحات  -

تاریخ انتشار 1999