A new detector for sub-millisecond EXAFS spectroscopy at the European Synchrotron Radiation Facility

نویسندگان

  • Innokenty Kantor
  • Jean-Claude Labiche
  • Emmanuel Collet
  • Laurent Siron
  • Jean-Jacques Thevenin
  • Cyril Ponchut
  • Jacques Borrel
  • Trevor Mairs
  • Carlo Marini
  • Cornelius Strohm
  • Olivier Mathon
  • Sakura Pascarelli
چکیده

A new FReLoN (Fast-Readout Low-Noise) high-frame-rate detector adopted for the fast continuous collection of X-ray absorption spectra is presented. The detector is installed on the energy-dispersive X-ray absorption beamline ID24 at the ESRF and is capable of full time-resolved EXAFS spectra collection with over 4 kHz repetition rate and 0.2 ms exposure time. An example of the in situ kinetic study of the high-temperature oxidation of metallic iron is presented.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quick-EXAFS implementation on the general purpose EXAFS beamline at ESRF

The new implementation of QEXAFS acquisition on the general purpose EXAFS beamline BM29 at the European Synchrotron Radiation Facility is presented. By adopting a continuous-scan mode, a high signal-to-noise ratio can be maintained, together with a fixed exit beam and full compatibility with step-by-step operation, while reducing acquisition times to a few seconds. The new equipment implemented...

متن کامل

The Time-resolved and Extreme-conditions XAS (TEXAS) facility at the European Synchrotron Radiation Facility: the energy-dispersive X-ray absorption spectroscopy beamline ID24

The European Synchrotron Radiation Facility has recently made available to the user community a facility totally dedicated to Time-resolved and Extreme-conditions X-ray Absorption Spectroscopy--TEXAS. Based on an upgrade of the former energy-dispersive XAS beamline ID24, it provides a unique experimental tool combining unprecedented brilliance (up to 10(14) photons s(-1) on a 4 µm × 4 µm FWHM s...

متن کامل

The time-resolved and extreme conditions XAS (TEXAS) facility at the European Synchrotron Radiation Facility: the general-purpose EXAFS bending-magnet beamline BM23

BM23 is the general-purpose EXAFS bending-magnet beamline at the ESRF, replacing the former BM29 beamline in the framework of the ESRF upgrade. Its mission is to serve the whole XAS user community by providing access to a basic service in addition to the many specialized instruments available at the ESRF. BM23 offers high signal-to-noise ratio EXAFS in a large energy range (5-75 keV), continuou...

متن کامل

A study of the coordination environment in aqueous cadmium-thiol complexes by EXAFS spectroscopy: experimental vs. theoretical standards.

Using EXAFS, we investigated the changes in the local structure of Cd(II) complexes formed with a series of low-molecular-weight thiols at different thiol/cadmium stoichiometries. For dilute solutions, a comparison of theoretical and experimental standards proved the latter approach superior. The number of bound oxygen atoms decreased while the number of sulfur atoms increased as the thiol/cadm...

متن کامل

Evaluating scintillator performance in time-resolved hard X-ray studies at synchrotron light sources

The short pulse duration, small effective source size and high flux of synchrotron radiation is ideally suited for probing a wide range of transient deformation processes in materials under extreme conditions. In this paper, the challenges of high-resolution time-resolved indirect X-ray detection are reviewed in the context of dynamic synchrotron experiments. In particular, the discussion is ta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2014