self-reinforced poly-levo-lactide and metallic devices in the fixation of femoral osteotomies an experimental study on rabbits and rats

نویسنده

  • Janne Viljanen
چکیده

................................................................................................................................................................... 7 list of original publications ....................................................................................................................... 8 list of abbreviations ......................................................................................................................................... 9 introduction......................................................................................................................................................... 11 review of the literature ............................................................................................................................... 13 Chemical structure of polylactide ........................................................................................................................................................13 Synthesis of polylactide.........................................................................................................................................................................13 Biodegradation of polylactide...............................................................................................................................................................13 Biocompatibility of polylactide ........................................................................................................................................................... 14 Mechanical properties of polylactide.................................................................................................................................................. 14 Experimental studies of polylactide devices....................................................................................................................................... 14 Clinical studies of polylactide devices ................................................................................................................................................ 18 Experimental studies and stress protection in the rigid and semi-rigid fi xation ...........................................................................20 Quantitative computed tomography (QCT) to quantify bone mineral non-invasively in the cancellous and cortical bone ....21 Magnetic resonance imaging (MRI) in the detection of polylactide in the cancellous and cortical bone.................................... 22 aims of the present study ............................................................................................................................. 25 materials and methods.................................................................................................................................. 27 Experimental animals ......................................................................................................................................................................... 27 Fixation devices..................................................................................................................................................................................... 27 Anaesthesia techniques ........................................................................................................................................................................28 Operation methods ...............................................................................................................................................................................28 Postoperative follow-up .......................................................................................................................................................................29 Preparation of the specimens ...............................................................................................................................................................29 Radiographic techniques ......................................................................................................................................................................29 Quantitative computed tomography (QCT) ......................................................................................................................................... 30 Magnetic resonance imaging (MRI) ..................................................................................................................................................... 30 Histological, histomorphometric , microradioraphic, and oxytetracycline (OTC) fl uorescence techniques ...............................31 Statistics .................................................................................................................................................................................................31 results.......................................................................................................................................................................33 Macroscopic results .............................................................................................................................................................................. 33 Radiographic results............................................................................................................................................................................. 33 Quantitative computed tomography (QCT) ......................................................................................................................................... 34 Magnetic resonance imaging (MRI) ..................................................................................................................................................... 37 Histological, histomorphometric , microradioraphic, and oxytetracycline (OTC) fl uorescence results..................................... 38 discussion............................................................................................................................................................... 45 conclusions........................................................................................................................................................... 49 acknowledgments ..............................................................................................................................................51 references.............................................................................................................................................................. 52 original publications ..................................................................................................................................... 58

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Self-reinforced bioabsorbable versus metallic fixation systems for metacarpal and phalangeal fractures: a biomechanical study.

Bioabsorbable fixation devices offer a useful option to treat small bone fractures of the hand if the prerequisite of reliable and stable osteofixation is met. We compared the stabilities of various bioabsorbable fixation devices with metallic fixation devices by using an oblique osteotomy model in radial to ulnar orientation. The 1.5-mm, self-reinforced, poly-L-lactide (SR-PLLA) pins provided ...

متن کامل

Absorbable pins of self-reinforced poly-L-lactic acid for fixation of fractures and osteotomies.

We reviewed 27 patients with small-fragment fractures or osteotomies treated by internal fixation with absorbable self-reinforced poly-L-lactide pins. The follow-up time ranged from eight to 37 months. The two most common indications were chevron osteotomy of the first metatarsal bone for hallux valgus and displaced fracture of the radial head. No redisplacements occurred, and there were no sig...

متن کامل

Bioabsorbable miniplating versus metallic fixation for metacarpal fractures.

Bioabsorbable implants offer an attractive alternative to metallic implants to stabilize small bone fractures in the hand. Self-reinforced bioabsorbable miniplating for metacarpal fractures was studied in bones from cadavers and compared with standard metallic fixation methods. One hundred twelve fresh-frozen metacarpals from humans had three-point bending and torsional loading after transverse...

متن کامل

Partial Resurfacing of the Distal Femoral Cartilage Defect with Stem Cell- Seeded Poly-Vinyl-Alcohol (PVA) Scaffold

Objective- To evaluate the biological compatibility of differentiated stem cells embedded in poly-vinyl-alcohol (PVA) scaffolds for repair of distal femoral cartilage defect.   Design- Experimental in vivo study. Animals- Twelve adult male New Zealand white rabbits were used which were divided into two groups (I, II) six rabbits each.   Procedures- Mesenchymal stem cells were isolated from h...

متن کامل