Compliance of Bhabhatron‐II telecobalt unit with IEC standard ‐ radiation safety

نویسندگان

  • G Sahani
  • Munish Kumar
  • PK Dash Sharma
  • DN Sharma
  • Kanta Chhokra
  • Bibekananda Mishra
  • SP Agarwal
  • RK Kher
چکیده

Bhabha Atomic Research Centre, Mumbai, India designed and developed a telecobalt unit, which was named as Bhabhatron-II. In this paper, the results pertaining to radiation safety of indigenously developed Bhabhatron-II telecobalt unit are reported. The various tests were carried out as per requirements of International Electrotechnical Commission standard and acceptance criteria developed nationally. Various devices such as CaSO4:Dy based thermoluminescent dosimeters, farmer type ionization chamber, water phantom and radiographic films were used. All the parameters pertaining to radiation leakage/transmission were within the tolerance limits as per IEC-60601-2-11 standard except the collimator transmission through X collimators (upper jaw), which marginally exceeds the tolerance limit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Physicist Description of Indigenous Telecobalt Machine Bhahbhatron-II TAW

The newly designed indigenous Bhabhatron-II is installed in our institution. The Telecobalt machines were put into use for Radiotherapy after the possibility of producing High activity sources with smaller dimension which satisfies the ideal requirement of Teletherapy source. The Bhabhatron II head can accommodate nearly 250RMM source strength. Being a computer controlled machine the Bhabhatron...

متن کامل

Development of Indigenous Source of Cobalt Suitable for Radiation Technology Applications

The role of Cobalt-60 as a radiation source in teletherapy for the treatment of cancer needs hardly to be reiterated. Although not used commonly in developed countries, cobalt-60 teletherapy machines can still be regarded as a very viable and cost effective option for the treatment of a sizeable fraction of cancer patients. At present in India, there are only 399 teletherapy units (280 telecoba...

متن کامل

A Monte Carlo simulation study on the effectiveness of electron filters designed for telecobalt radiation therapy treatment

Background: The aim of present study was to analyze the effectiveness of electron filters in the Telecobalt radiotherapy treatment by simulation technique.  Materials and Methods: The BEAMnrc Monte Carlo code was used to simulate the electron filters of thickness of 0.5 gm/cm2 below the trimmer bar for 35 × 35 cm2 field size in Theratron Equinox-80 telecobalt unit. The electron filters were mad...

متن کامل

Is your current safety system compliant to today's safety standard?

It is estimated that about 66% of the Programmable Electronic Systems (PES) running in the process industry were installed before the publication of today’s commonly used safety standards (IEC 61508 and IEC 61511/ISA 84) Some of those safety systems, particularly the ones installed between the late 1980's and early 2000, are either 1. General-purpose PLCs, 2. Not designed or certified according...

متن کامل

Design, implementation and validation of a motorized wedge filter for a telecobalt machine (Bhabhatron-II).

A universal wedge filter of 15W × 20 cm(2) and 60° nominal wedge angle is designed and placed between the collimating jaws and penumbra trimmers inside the treatment head. A pneumatically driven actuating mechanism toggles the wedge between the wedge IN position and wedge OUT position. The effective wedge angles were determined using an analytical formula. An accumulated wedge profile at a dept...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -