System for simplified discontinuous-gradient polyacrylamide-gel electrophoresis.

نویسندگان

  • D P Zais
  • R C Roberts
چکیده

We describe a modified polyacrylamide gel electrophoresis method with which plasma proteins are excellently resolved in 4 h. We made a three-layer discontinuous gradient gel with concentrations of 80,60, and 45 g of polyacrylamide per liter of tris(hydroxymethyl)aminomethane/ethylenediaminetetraacetic acid/borate buffer, pH 9.2. Time and material needed in the preparation of the gel was greatly decreased, a well-resolved (22-25 bands) pattern was obtained in 1 h, and the gel slabs were easier to remove from the cell than were gels prepared according to the manufacturer's specifications. We saw a marked shift in the higher polymers of haptoglobin type 2-2 toward the cathode in this system, and also a clearly resolved double band of alpha2-macroglobulin in whichthe more anodal band appears to represent alpha2-macroglobulin/protease complex.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using a Temperature Gradient against the Time in Polyacrylamide Gel Electrophoresis May Eliminate the Need for Stacking Gels

Background and Objectives: Making stacking gels for polyacrylamide gels in the laboratory by conventional methods is laborious and time consuming. Considering the role of temperature in polyacrylamide gels with respect to electrical resistance and viscosity, we assumed that decreasing the temperature would cause an increase in electrical resistance and viscosity.  Ultimately, a downward tempera...

متن کامل

Discontinuous electrophoresis on polyacrylamide gel slab.

D ISCOT1XUOUS ELECT1IO1’HORESIS in polyacrylamide rods has been used for separation of serum proteins (1). In spite of satisfactory resolution in tile rod, the technic renhains cumbersome, and comparison of the closely migrating cOnlpoflents inaccurate. Akroyd (2) reported discontinuous electrophoresis On polyacrylamide gel slab, which alleviates many of the difficulties of the rod. We llave co...

متن کامل

Evaluation of commonly used electrophoretic methods for the analysis of proteins and peptides and their application to biotechnology

This account gives an overview and evaluation of the current methods of most commonly used electrophoretic techniques in the analysis of various polypeptides. A general review of some background information and pitfalls associated with the application of these methods in the characterization of the size and charge properties of proteins or peptides is presented. It is intended to provide some g...

متن کامل

Useful buffer and gel systems for polyacrylamide gel electrophoresis.

Seven buffer and gel systems for polyacrylamide gel electrophoresis using discontinuous voltage and pH gradients (disc electrophoresis according to ORNSTEIN-UAVIS) and five systems using discontinuous voltage gradients at constant pH (according to ALLEN) have been compiled and characterized. Usefulness and applicability of the systems for clinical investigations are discussed and illustrated by...

متن کامل

Multiple forms of acetylcholinesterase from pig brain.

1. A number of methods of solubilization of pig brain acetylcholinesterase (EC 3.1.1.7) were studied. The multiple enzymic forms of the resultant preparations were examined by polyacrylamide-gel electrophoresis. 2. Butanol extraction, Nagarase treatment and ultrasonication proved unsuitable as preparatory methods, but detergent treatment (Triton X-100, Triton X-100-KCl and lysolecithin) gave go...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 23 3  شماره 

صفحات  -

تاریخ انتشار 1977