Defibrillation efficacy of different electrode placements in a human thorax model.

نویسندگان

  • A L de Jongh
  • E G Entcheva
  • J A Replogle
  • R S Booker
  • B H Kenknight
  • F J Claydon
چکیده

The objective of this study was to measure the defibrillation threshold (DFT) associated with different electrode placements using a three-dimensional anatomically realistic finite element model of the human thorax. Coil electrodes (Endotak DSP, model 125, Guidant/CPI) were placed in the RV apex along the lateral wall (RV), withdrawn 10 mm away from the RV apex along the lateral wall (RVprox), in the RV apex along the anterior septum (RVseptal), and in the SVC. An active pulse generator (can) was placed in the subcutaneous prepectoral space. Five electrode configurations were studied: RV-->SVC, RVprox-->SVC, RVSEPTAL-->SVC, RV-->Can, and RV-->SVC + Can. DFTs are defined as the energy required to produce a potential gradient of at least 5 V/cm in 95% of the ventricular myocardium. DFTs for RV-->SVC, RVprox-->SVC, RVseptal-->SVC, RV-->Can, and RV-->SVC + Can were 10, 16, 7, 9, and 6 J, respectively. The DFTs measured at each configuration fell within one standard deviation of the mean DFTs reported in clinical studies using the Endotak leads. The relative changes in DFT among electrode configurations also compared favorably. This computer model allows measurements of DFT or other defibrillation parameters with several different electrode configurations saving time and cost of clinical studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A computer model for the study of electrical current flow in the human thorax.

Electrocardiography has played an important role in the detection and characterization of heart function, both in normal and abnormal states. In this paper we present an inhomogeneous, anisotropic computer model of the human thorax for use in electrocardiography with emphasis on the calculation of transthoracic potential and current distributions. Knowledge of the current pathways in the thorax...

متن کامل

A Patient-specific Computational Study of Transvenous Defibrillation

The goal of this study is to assess the predictive capacity of computational models of transvenous defibrillation by comparing the results of patient-specific simulations to clinically determined defibrillation metrics. Solutions for seven patient-specific models have been completed. The 3-D models of the thorax and in situ electrodes were created from segmented CT images taken shortly after im...

متن کامل

Effect of pulse separation between two sequential biphasic shocks given over different lead configurations on ventricular defibrillation efficacy.

BACKGROUND Two sequential biphasic shocks delivered over separate lead configurations markedly improve defibrillation efficacy compared with a single shock alone. We investigated the effect of varying the intershock interval between sequential biphasic shocks on defibrillation. METHODS AND RESULTS Defibrillation thresholds (DFTs) were obtained in six dogs for shock separations ranging from 0....

متن کامل

Transvenous defibrillation in humans via the coronary sinus.

A consistently effective transvenous defibrillation system for use in automatic defibrillators could significantly alter the approach to patients at risk of sudden death. Transvenous defibrillation systems that use a right ventricular (RV) electrode only or an RV electrode in combination with a chest patch are relatively inefficient at applying current to the posterolateral left ventricle. An R...

متن کامل

Effects of polarity for monophasic and biphasic shocks on defibrillation efficacy with an endocardial system.

Electrode polarity has been reported to be one of the factors that affect defibrillation efficacy. We studied the influence of polarity on defibrillation efficacy when monophasic and biphasic waveforms were used with an endocardial lead system. In six anesthetized pigs, defibrillation catheters were placed in the right ventricular (RV) apex and at the junction of the superior vena cava (SVC) an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 22 1 Pt 2  شماره 

صفحات  -

تاریخ انتشار 1999