PURPOSE To prospectively compare subjective radiological quality, radiation dose and effect on workflow using digital radiography (DR) vs. conventional screen film (SF) radiography in the Small Bowel Follow-Through (SBFT) examination. METHODS Five attending and four resident radiologists compared hard-copy images from 11 SBFT examinations, for which every patient had a defined pair of SF and DR images taken 20-30 min apart. SF and DR were performed with equivalent exposure data. Overall image quality, intestinal mucosa definition and bone visualization were graded on a 5-point scale, with 5 being the highest value. Thus, 11 patients had three criteria judged by nine observers in two modalities for a total of 594 observations of image quality. The radiation doses and effect on workflow were also compared. Statistical analysis was performed with the Mann-Whitney U test. RESULTS The mean scores on DR and SF for overall image quality, intestinal mucosa definition and bone visualization were 4.49 vs. 3.17, 4.38 vs. 3.4, and 4.5 vs. 2.4, respectively (p<0.001 in all cases). The average radiation dose with DR was 0.93+/-0.54 cGy, and -1.58+/-0.63 cGy with SF (p=0.016), reflecting a 41% dose reduction. Production of a DR image by technicians took 3.5+/-1.3 min vs. 5.5+/-1.5 min for SF (p=0.002). CONCLUSION Subjective image quality of hard-copy digital radiographs of the small bowel through examination is superior to images obtained with conventional radiographs, with an associated reduction of 41% in radiation dose and increased efficiency.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of the effectiveness of Mammographic Film-Screen and Standard Film-Screen in the Detection of Small Bone Fractures

The use of mammography film-screen is limited in general radiography. The purpose of this study was to compare the effectiveness of mammographic film-screen and standard film-screen systems in the detection of small bone fractures. Radiographs were taken from patients' extremities and neck areas using mammography film-screen and standard film-screen (n=57 each). Fourteen other radiographs were ...

متن کامل

مقایسه دقت تصاویر رادیوگرافی

Statement of Problem: Computer Sciences, in radiology, like other fields, is of high importance. It should also be noted that the accuracy of the technique and work conditions affects the radiographs information considerably. There for, in order to get more accurate diagnostic information, it seems necessary to investigate different digitized radiographic techniques and to compare them with the...

متن کامل

Digitally Scanned Radiographs versus Conventional Films for Determining Clarity of Periapical Lesions and Quality of Root Canal Treatment

Aim To compare digital images of conventional radiographs with the original radiographs for perceived clarity of periapical lesions and the quality of root canal treatment. Materials and Methods One hundred and four intraoral periapical radiographs of patients with endodontically treated teeth were randomly selected. The radiographs were digitized using an MD300 USB X-ray Reader. The digital ...

متن کامل

Diagnostic Accuracy of Digitized Images Using Different Resolution Settings of Digital Camera in Detection of Proximal Caries

Objective: When none of digital systems and scanners is accessible and it is essential to have digitized images of conventional radiographs, digital cameras can be used. The Aim of this study was to investigate whether digital images obtained by different resolutions of a digital camera are matched to the original radiographs in evaluation of caries. Methods: In this diagnostic accuracy in v...

متن کامل

بررسی دقت پانورامیک دیجیتال در تشخیص پوسیدگی‌های پروگزیمال

Background and Aims: Conventional radiological equipments in our country are going to be converted to digital system using computed radiology (CR) technology. If we know the accuracy of digital panoramic radiography for detection of small defects in tooth, it will be useful in cases with difficulty for taking the intraoral radiographs. The aim of this study was to evaluate sensitivity and speci...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society

دوره 32 7  شماره 

صفحات  -

تاریخ انتشار 2008