Beam Position-phase Monitors for Sns Linac
نویسنده
چکیده
Electromagnetic modeling with MAFIA of the combined beam position-phase monitors (BPPMs) for the Spallation Neutron Source (SNS) linac has been performed. Time-domain 3-D simulations are used to compute the signal amplitudes and phases on the BPPM electrodes for a given processing frequency, 402.5 MHz or 805 MHz, as functions of the beam transverse position. Working with a summed signal from all the BPPM electrodes provides a good way to measure accurately the beam phase. While for an off-axis beam the signal phases on the individual electrodes can differ from those for a centered beam by a few degrees, the phase of the summed signal is found to be independent of the beam transverse position inside the device. Based on the analysis results, an optimal BPPM design with 4 one-end-shorted 60degree electrodes has been chosen. It provides a good linearity and sufficient signal power for both position and phase measurements, while satisfying the linac geometrical constrains and mechanical requirements.
منابع مشابه
Beam Position Monitors for the Sns Linac
The Spallation Neutron Source (SNS) linac accelerates 52-mA peak of pulsed Hparticles to over 800 MeV. There are three types of accelerating structure in which the beam position must be measured: the drift-tube-linac (DTL); cavity-coupled-linac (CCL); and superconducting-linac (SCL)[1,2]. Beam with a 402.5-MHz structure is injected into a 402.5 MHz DTL, followed by 805-MHz CCL and SCL structure...
متن کاملThe Sns Beam Diagnostics Experience and Lessons Learned
The Spallation Neutron Source accelerator systems are designed to deliver a 1.0 GeV, 1.4 MW proton beam to a liquid mercury target for neutron scattering research. The accelerator complex consists of an Hinjector, capable of producing one-ms-long pulses at 60 Hz repetition rate with 38 mA peak current; a 1 GeV linear accelerator; an accumulator ring; and associated transport lines. The accelera...
متن کاملA Quest for Measuring Ion Bunch Longitudinal Profiles with One Picosecond Accuracy in the Sns Linac
The SNS linac utilizes several accelerating structures operating at different frequencies and with different transverse focusing structures. Low-loss beam transport requires careful matching at the transition points for both the transverse and longitudinal plane. Longitudinal beam parameters are measured using four Bunch Shape Monitors (used at many ion accelerator facilities, aka Feschenko dev...
متن کاملReview of Diagnostics for next Generation Linear Accelerators
New electron linac designs incorporate substantial advances in critical beam parameters such as beam loading and bunch length and will require new levels of performance in stability and phase space control. In the coming decade, e(and e+) linacs will be built for a high power linear collider (TESLA, CLIC, JLC/NLC), for fourth generation X-ray sources (TESLA FEL, LCLS, Spring 8 FEL) and for basi...
متن کاملLaser Based Diagnostics for Measuring H Beam Parameters
In recent years, a number of laser based H beam diagnostics systems have been developed in the Spallation Neutron Source (SNS). This talk reviews three types of laser based diagnostics at SNS: the laser wire profile monitors at superconducting linac (SCL), the laser transverse emittance scanner at high energy beam transport (HEBT), and the laser bunch shape monitor at medium energy beam transpo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2000