Variation of Densitometry on Computed Tomography in COPD – Influence of Different Software Tools
نویسندگان
چکیده
OBJECTIVES Quantitative multidetector computed tomography (MDCT) as a potential biomarker is increasingly used for severity assessment of emphysema in chronic obstructive pulmonary disease (COPD). Aim of this study was to evaluate the user-independent measurement variability between five different fully-automatic densitometry software tools. MATERIAL AND METHODS MDCT and full-body plethysmography incl. forced expiratory volume in 1s and total lung capacity were available for 49 patients with advanced COPD (age = 64±9 years, forced expiratory volume in 1 s = 31±6% predicted). Measurement variation regarding lung volume, emphysema volume, emphysema index, and mean lung density was evaluated for two scientific and three commercially available lung densitometry software tools designed to analyze MDCT from different scanner types. RESULTS One scientific tool and one commercial tool failed to process most or all datasets, respectively, and were excluded. One scientific and another commercial tool analyzed 49, the remaining commercial tool 30 datasets. Lung volume, emphysema volume, emphysema index and mean lung density were significantly different amongst these three tools (p<0.001). Limits of agreement for lung volume were [-0.195, -0.052 l], [-0.305, -0.131 l], and [-0.123, -0.052 l] with correlation coefficients of r = 1.00 each. Limits of agreement for emphysema index were [-6.2, 2.9%], [-27.0, 16.9%], and [-25.5, 18.8%], with r = 0.79 to 0.98. Correlation of lung volume with total lung capacity was good to excellent (r = 0.77 to 0.91, p<0.001), but segmented lung volume (6.7±1.3-6.8±1.3 l) were significantly lower than total lung capacity (7.7±1.7 l, p<0.001). CONCLUSIONS Technical incompatibilities hindered evaluation of two of five tools. The remaining three showed significant measurement variation for emphysema, hampering quantitative MDCT as a biomarker in COPD. Follow-up studies should currently use identical software, and standardization efforts should encompass software as well.
منابع مشابه
Comment on “Computed Tomography Imaging Findings in Chemical Warfare Victims with Pulmonary Complications”
Dr.Mirsadraei and colleagues performed an interesting study about the lung HRCT findings in chemical warfare patients who suffering from long-term pulmonary complications. They found that air trapping and mosaic attenuation were the most common lung HRCT findings. Also they divided patients in different clinical entities according to the lung HRCT findings (Bronchiolitis Oblitrans, pulmonary fi...
متن کاملImpact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملEvaluation of Effect of Different Computed Tomography Scanning Protocols on Hounsfield Unit and Its Impact on Dose Calculation by Treatment Planning System
Introduction: In radiotherapy treatment planning system (TPS), basic input is the data from computed tomography (CT) scan, which takes into account the effect of inhomogeneities in dose calculations. Measurement of CT numbers may be affected by scanner-specific parameters. Therefore, it is important to verify the effect of different CT scanning protocols on Hounsfield unit (HU) and its impact o...
متن کاملCone-beam computed tomography performance and endodontic filling material influence in the diagnosis of horizontal root fracture
Introduction: The aim of this study was to investigate the accuracy of Cone-beam computed tomography(CBCT) in detecting the horizontal root fractures (HRFs) in teeth with and without gutta-percha. Materials & Methods: This in vitro study was performed on 100 mandibular and maxillary single-rooted teeth. In 55 samples, the canals were prepared. Then, the horizontal fracture was induced randomly...
متن کاملSectional Anatomy Quiz - V
In this series a pictorial quiz pertaining to identification of normal anatomical structures and landmarks at a given level on the computed tomography (CT) is presented. An image depicting normal anatomy is followed by a series of images showing different pathologies. Readers are expected to identify and appreciate variation and changes in the normal anatomy in presence of a given pathology. Th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2014