Measurement of axial length of eyes with incomplete filling of silicone oil in the vitreous cavity using x ray computed tomography.

نویسندگان

  • Kazuo Takei
  • Yasuo Sekine
  • Fumiki Okamoto
  • Sachiko Hommura
چکیده

AIMS To establish a reliable method for measuring the axial length of the eye with incomplete filling of silicone oil in the vitreous cavity in order to determine the IOL power before executing combined cataract surgery and silicone oil removal. METHODS 12 eyes of 12 patients undergoing combined cataract extraction and silicone oil removal between October 1998 and June 2000 were entered prospectively into this study. All eyes were examined using an x ray computed tomography (CT) scanner. Each axial length of a silicone oil injected eye was measured on the best CT slice among eyeball cuts, which showed both the insertions of the medial and lateral rectus muscle, the thickest slice of the lens, and the optic nerve. The IOL power for the eyes was determined using the SRK/T formula based on the CT data. The deviation of postoperative refraction from the goal refraction was evaluated for each eye. RESULTS The CT slices demonstrated that the vitreous cavity was not completely filled with the oil in all of the silicone oil injected eyes. The deviation of postoperative refraction from the goal refraction was less than 1 dioptre (D) error in six of 12 eyes (50%), and was less than 2 D error in nine eyes (75%). In the other three eyes having more than 2 D error, the axial length was 27 mm or more. CONCLUSION The CT measurement of axial eye length for determining IOL might be a useful method for evaluating silicone oil injected eyes before combined cataract surgery and silicone oil removal.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode

Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging tec...

متن کامل

Intraocular Silicone Oil Masquerading as Terson Syndrome

Introduction. Terson syndrome is described as intraocular hemorrhage in association with any type of intracranial hemorrhage and is associated with higher mortality rate and vision loss. Intraocular hemorrhage in Terson syndrome may be diagnosed using computed tomography but there are false positive results. Silicone oil which is widely used for internal tamponade of complicated retinal detachm...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

A Novel Episcleral Macular Buckling: Wire-Strengthened Sponge Exoplant for Recurrent Macular Hole and Retinal Detachment in High Myopic Eyes

The purpose would be to describe and evaluate a novel technique of episcleral macular buckling in postvitrectomy recurrent macular hole retinal detachment in highly myopic eyes. A 7mm silicone sponge strengthened with a U-shaped 0.5mm orthodontics stainless steel wire fed along its length and hand-bent to produce L-shaped buckle of appropriate shape and length, is used. The episcleral macular b...

متن کامل

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 86 1  شماره 

صفحات  -

تاریخ انتشار 2002