Nanoparticle labelling-based magnetic immunoassay on chip combined with electrothermal vaporization-inductively coupled plasma mass spectrometry for the determination of carcinoembryonic antigen in human serum.

نویسندگان

  • Beibei Chen
  • Bin Hu
  • Ping Jiang
  • Man He
  • Hanyong Peng
  • Xing Zhang
چکیده

A sensitive and selective on chip magnetic immunoassay method, based on a sandwich-type immunoreaction with PbS nanoparticle (NPs) labels in combination with electrothermal vaporization-inductively coupled plasma mass spectrometry (ETV-ICP-MS), was proposed for the determination of carcinoembryonic antigen (CEA). We designed and fabricated a microfluidic chip for magnetic immunoassay, and the prepared iminodiacetic acid modified silica coated magnetic nanoparticles (IDA-SCMNPs) were packed into the central microchannel to form a solid phase column by self-assembly under the magnetic field. After completion of the immunoreaction involving a primary antibody, CEA and a secondary antibody labeled with PbS NPs on a magnetic solid phase packed-column, ETV-ICP-MS was used to determine the concentration of Pb that was released from the captured PbS NPs using an acid-dissolution step. The concentrations of CEA can be correlated with that of Pb. The established method demonstrated a limit of detection of 0.058 μg L(-1) for CEA, with a relative standard deviation (RSD) of 6.7% (c = 10 μg L(-1), n = 7). A linearity ranging from 0.2 μg L(-1) to 50 μg L(-1) and a 2-fold enrichment factor (from 60 μL sample solution to 30 μL eluent) were achieved. The proposed method was further validated by analyzing CEA in human serum. The results were in good agreement with those obtained by chemiluminescent immunoassay, which is currently used as a clinical method. Overall, this method offers the advantages of high speed, high sensitivity, high selectivity, low sample/reagents consumption, high integrity and versatility. Moreover, it can be easily applied to other biological and medical assays.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Cu, Zn, Cd and Pb in ®sh samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry

Ultrasonic slurry sampling electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry (USSETV-ID-ICP-MS) has been applied to the determination of Cu, Zn, Cd and Pb in several ®sh reference samples. NH4NO3 was added to the sample solution to work as a modi®er. Since the sensitivity of the elements studied in ®sh slurry and aqueous solution was quite different, isot...

متن کامل

Determination of cadmium and lead in urine by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry.

Electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry (ETV-ID-ICP-MS) was applied to the determination of Cd and Pb in urine samples. The isotope ratios for each element in each analytical run were calculated from the peak areas of each isotope. A relatively low vaporization temperature was used, which separated the analyte from the major matrix components an...

متن کامل

Determination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression

A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...

متن کامل

Direct determination of trace impurities in niobium pentaoxide solid powder with slurry sampling fluorination assisted electrothermal vaporization inductively coupled plasma mass spectrometry

A method of fluorination assisted electrothermal vaporization inductively coupled plasma mass spectrometry (FETV-ICP-MS) was developed to directly determine the trace impurities in niobium pentaoxide solid powder in which a poly(tetrafluoroethylene) (PTFE) emulsion was used as fluorinating modifier to promote the vaporization of refractory elements from a graphite furnace and to avoid the forma...

متن کامل

Determination of sulfur in fossil fuels by isotope dilution electrothermal vaporization inductively coupled plasma mass spectrometry

The determination of S by solution nebulization quadrupole inductively coupled plasma mass spectrometry (ICP-MS) is dif®cult because of interferences from oxygen dimer ions. The large O2 z ion current from the solvent water is a serious interference at S, the most abundant of the four isotopes, and precludes its measurement. The isotopic composition of S varies in nature as a consequence of nat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Analyst

دوره 136 19  شماره 

صفحات  -