Renal Function and Outcomes With Use of Left Ventricular Assist Device Implantation and Inotropes in End-Stage Heart Failure: A Retrospective Single Center Study
نویسندگان
چکیده
BACKGROUND Left ventricular assist device (LVAD) and inotrope therapy serve as a bridge to transplant (BTT) or as destination therapy in patients who are not heart transplant candidates. End-stage heart failure patients often have impaired renal function, and renal outcomes after LVAD therapy versus inotrope therapy have not been evaluated. METHODS In this study, 169 patients with continuous flow LVAD therapy and 20 patients with continuous intravenous inotrope therapy were analyzed. The two groups were evaluated at baseline and at 3 and 6 months after LVAD or inotrope therapy was started. The incidence of acute kidney injury (AKI), need for renal replacement therapy (RRT), BTT rate, and mortality for 6 months following LVAD or inotrope therapy were studied. Results between the groups were compared using Mann-Whitney U test and Chi-square with continuity correction or Fischer's exact at the significance level of 0.05. RESULTS Mean glomerular filtration rate (GFR) was not statistically different between the two groups, with P = 0.471, 0.429, and 0.847 at baseline, 3 and 6 months, respectively. The incidence of AKI, RRT, and BTT was not statistically different. Mortality was less in the inotrope group (P < 0.001). CONCLUSION Intravenous inotrope therapy in end-stage heart failure patients is non-inferior for mortality, incidence of AKI, need for RRT, and renal function for 6-month follow-up when compared to LVAD therapy. Further studies are needed to compare the effectiveness of inotropes versus LVAD implantation on renal function and outcomes over a longer time period.
منابع مشابه
Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملRight ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes.
OBJECTIVE The aim of this study was to evaluate the incidence, risk factors, and effect on outcomes of right ventricular failure in a large population of patients implanted with continuous-flow left ventricular assist devices. METHODS Patients (n = 484) enrolled in the HeartMate II left ventricular assist device (Thoratec, Pleasanton, Calif) bridge-to-transplantation clinical trial were exami...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملRight ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease
Introduction: In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...
متن کاملImplantation of left ventricular support under extracorporeal membrane oxygenation.
Continuous-flow left ventricular assist devices (LVADs) are used to manage patients with end-stage heart failure. Protection of right ventricular (RV) function is important during LVAD implantation, but sometimes patients require temporary RV support. We describe the technique of LVAD implantation under extracorporeal membrane oxygenation (ECMO) we use in our center. This technique allows soft ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2017