Simulated cup/disc ratio: a tool for ophthalmologists.

نویسندگان

  • Carolina Pelegrini Barbosa
  • Pedro Felipe Angelini
  • Paulo Schor
  • Augusto Paranhos Junior
چکیده

PURPOSE To evaluate and compare the observers' ability to measure simulations of cup/disc ratios (CDR) as concentric and non-concentric circles. METHODS In a prospective, random, and masked setting, 43 images representing the CDR spectrum from 0.2 to 0.9 for vertical and horizontal CDR measurements were developed and presented on a computer screen to 171 participants. RESULTS There were satisfactory agreements according to the kappa coefficient (0.755 and 0.730 for horizontal and vertical cup disc ratios, respectively) and Lin's concordance correlation (R=0.88 and R=0.86 for horizontal and vertical measurements, respectively). However, very poor agreement was found for intermediate CDR values. The worst agreement occurred when the CDR was between 0.4 and 0.6 for both the horizontal and vertical values. The kappa coefficient was 0.37 and 0.39 for 0.4 CDR (horizontal and vertical, respectively), 0.39 and 0.38 for 0.5 CDR (horizontal and vertical, respectively) and 0.45 and 0.41 for 0.6 CDR (horizontal and vertical, respectively). CONCLUSION Despite a good general agreement between the gold standard and the participants' responses, the absolute agreement for intermediate CDR values was very poor for both horizontal and vertical values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Disc damage likelihood scale.

G laucoma is a disease characterised by apoptotic ganglion cell death related, at least in part, to intraocular pressure. Any examination for glaucoma must therefore include some comment upon the health of these cells. Unfortunately, it is difficult to examine the ganglion cell layer ophthalmoscopically and so ophthalmologists typically rely on an analysis of a more visible ocular structure—the...

متن کامل

Vertical cup-to-disc ratio measurement for diagnosis of glaucoma on fundus images [7624-121]

Glaucoma is a leading cause of permanent blindness. Retinal fundus image examination is useful for early detection of glaucoma. In order to evaluate the presence of glaucoma, the ophthalmologists determine the cup and disc areas and they diagnose glaucoma using a vertical cup-to-disc ratio. However, determination of the cup area is very difficult, thus we propose a method to measure the cup-to-...

متن کامل

Glaucoma Detection in Color Fundus Images Using Cup to Disc Ratio

-----------------------------------------------ABSTRACT---------------------------------------------------------GLAUCOMA is a group of diseases that can damage the eye’s optic nerve and result in vision loss and permanent blindness. Glaucoma is a disease characterized by elevated intraocular pressure (IOP). This increased IOP leads to damage of optic nerve axons at the back of the eye, with eve...

متن کامل

An Automatic Image Processing System for Glaucoma Screening

Horizontal and vertical cup to disc ratios are the most crucial parameters used clinically to detect glaucoma or monitor its progress and are manually evaluated from retinal fundus images of the optic nerve head. Due to the rarity of the glaucoma experts as well as the increasing in glaucoma's population, an automatically calculated horizontal and vertical cup to disc ratios (HCDR and VCDR, res...

متن کامل

Ocular dimensions in low tension glaucoma compared with open-angle glaucoma and the normal.

Pathological excavation of the optic disc in the apparent absence of raised ocular tension was first described by von Graefe (1857), and since then it has aroused interest among ophthalmologists; various names have been given to it and these have reflected ideas about its aetiology. Schnabel (I885) described a cavernous optic atrophy which he believed had resulted from progressive diminution of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de oftalmologia

دوره 73 4  شماره 

صفحات  -

تاریخ انتشار 2010