A standard, noninvasive monitoring of hematocrit algorithm improves blood pressure control in pediatric hemodialysis patients.

نویسندگان

  • Hiren P Patel
  • Stuart L Goldstein
  • John D Mahan
  • Beth Smith
  • Cheryl B Fried
  • Helen Currier
  • Joseph T Flynn
چکیده

Accurate dry weight assessment is difficult in pediatric hemodialysis patients but is essential to prevent chronic fluid overload, hypertension, and cardiovascular morbidity. A noninvasive monitoring (NIVM) of hematocrit-guided ultrafiltration algorithm was studied prospectively in 20 pediatric hemodialysis patients. The algorithm targeted the first 50% of total goal ultrafiltration to be removed during the first hour of dialysis with a maximum blood volume change of 8 to 12% per hour. The second 50% was removed during the remaining treatment time with a maximum blood volume change of 5% per hour. Data that were collected at baseline and 6 mo included weight, BP, number of antihypertensive medications, 24-h ambulatory BP monitoring (ABPM), echocardiogram, and ultrafiltration-associated symptoms. Sixteen of 20 enrolled patients completed the study. No difference was seen between baseline and 6-mo weight, predialysis casual BP, nighttime ABPM, or left ventricular mass index. There was a decrease in postdialysis casual systolic BP, daytime ABPM, number of antihypertensive medications prescribed, and rate of intradialytic events related to ultrafiltration (all P < or = 0.05). Adoption of a standardized NIVM-guided algorithm led to (1) improved ABPM profiles, (2) decreased antihypertensive medication burden, and (3) decreased ultrafiltration-associated symptoms. Wider use of NIVM-guided ultrafiltration may decrease cardiovascular morbidity in pediatric hemodialysis patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noninvasive interventions to decrease hospitalization and associated costs for pediatric patients receiving hemodialysis.

Minimal pediatric data describe hospitalization causes and associated costs for children who receive maintenance hemodialysis, and no data exist to evaluate methods to decrease hospitalization. In 1999, two common causes of hemodialysis patient hospitalization at Texas Children's Hospital were fluid overload/hypertension (FO/HTN) and vascular access thrombosis (VAT). Evaluated is the effect of ...

متن کامل

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

ارائه مدلی تصمیم‌یار جهت پایش پیوسته فشارخون بیماران با استفاده از شبکه عصبی مصنوعی و نمودار کنترل‌کیفیت‌آماری

Background: Heart patients with hypertension and myocardial infarction and hemodialysis patients are at risk of lowering of blood pressure during hemodialysis. Therefore, continuous monitoring of blood pressure in health centers is a priority for deciding the type of therapeutic treatment in these patients. The aim of this study was to provide a decision-making model based on neural network and...

متن کامل

The effectiveness of acceptance and commitment therapy in quality of life and blood pressure index of hemodialysis patients

Background: Dialysis patients are prone to various complications of trhe disease such as physical, economic, social, and psychological problems. The current study aimed to evaluate the effectiveness of acceptance and commitment therapy on quality of life and blood pressure in hemodialysis patients. Materials and methods: This quasi-experimental study was conducted with a pretest-posttest...

متن کامل

Continuous noninvasive in vivo monitoring of intravascular plasma volume and hematocrit changes during hemodialysis in humans: direct comparison with the CRIT-LINE

We report a new device and algorithm that allows simultaneous monitoring of the hematocrit and plasma volume fraction of blood within the intravascular space of an optically probed volume of skin. Skin is probed with a near infrared (NIR) laser and simultaneously collecting the Rayleigh and Mie scattered light as one raw signal and the undifferentiated Raman and fluorescence emission as the sec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical journal of the American Society of Nephrology : CJASN

دوره 2 2  شماره 

صفحات  -

تاریخ انتشار 2007