Comparison of blood glucose measurements using samples obtained from the forearm, finger skin puncture, and venous serum.
نویسندگان
چکیده
BACKGROUND Blood glucose testing (BGT) at the forearm minimizes the pain experienced during sampling of capillary blood. We compared the BGT results for forearm sampling with those for standard finger skin puncture and venous serum to evaluate the clinical validity of forearm BGT. METHODS BGT was performed on the finger (G(F)) and forearm (G(A)) with a portable glucometer in 555 subjects, including 61 diabetic patients, under fasting conditions. BGT with venous serum (G(V)) was followed within an hour in 514 subjects. Simple linear regression, intraclass correlation, and Passing-Bablok regression analyses were performed using the G(A)-G(F) and G(A)-G(V) data. RESULTS G(A) showed an excellent linear relationship with both G(F) and G(V) with a Pearson correlation coefficient (r) of 0.97 (P<0.0001) in the patient group, which was similar to the findings in the normal group except for the lower r values. The mean bias between G(A) and G(F) and between G(A) and G(V) were within +/- 10 mg/dL in both groups. The intraclass correlation coefficients were slightly smaller than the corresponding r values, but they showed the same tendency in both groups. In the Passing-Bablok analyses, the 95% confidence intervals of the slope and intercept parameters were <+/-20% of unity and <+/-20 mg/dL, respectively, which were within the acceptable ranges. All 3 statistical analyses supported the satisfactory agreement of G(A) with G(F) or G(V). CONCLUSIONS BGT at the forearm was highly consistent with the standard BGT, thereby confirming its applicability in clinical practice for self-testing under steady fasting conditions.
منابع مشابه
Forearm blood glucose testing in diabetes mellitus.
AIMS To compare the accuracy and acceptability of capillary blood glucose testing from the forearm with finger prick testing in diabetic children. METHODS Blood glucose measurements from samples taken from the forearm and the finger were compared in an outpatient setting from 52 children and adolescents with diabetes mellitus aged 6-17 years. Opinions on forearm sampling were collected by que...
متن کاملA Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia
Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of ...
متن کاملComparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs
Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...
متن کاملGlucose Measurements Using Blood Extracted from the Forearm and the Finger
Using the FreeStyle blood glucose monitor that measures glucose in a 0.3 μl blood sample, blood from the fingertip and blood from the forearm were measured for glucose concentration. There was a difference in glucose concentration between these sites. A linear regression of glucose measurements from the arm versus those from the finger in blood samples from diabetic patients taken at random tim...
متن کاملSimultaneously obtained skin-puncture serum, skin-puncture plasma, and venous serum compared, and effects of warming the skin before puncture.
Specimens of skin-puncture serum and plasma and venous serum were simultaneously obtained from healthy adults and in each specimen the concentrations of 12 chemical constituents were measured. No clinically important difference was found in the concentrations of the constituents measured in skin-puncture serum and plasma with or without warming the skin before puncture. When the concentration o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Korean journal of laboratory medicine
دوره 30 3 شماره
صفحات -
تاریخ انتشار 2010