Morphology of Tissue Reaction in Rats after Subcutaneous Implantation of Porcine Pericardium and Aortic Valve Leaflets Devitalized by Cryoradiation
ثبت نشده
چکیده
The decrease of immunogenicity is a priority requirement to pre-implantation treatment of the xenogeneic graft tissue. To create tissue implants of the pericardium and aortic valve leaflets, we have developed a method of devitalizing treatment, based on the combined effect of low temperatures (-196 °C) and ionizing β-radiation. This approach provides deletion to the main targets of biomaterial immunogenicity due to the effects of successive cryoand radiation damage, as well as the activation of radiation-induced apoptosis. The purpose of research was to assess the impact of low-temperature and radiation and their synergistic effect on the biocompatibility of devitalized xenogeneic tissues. METHODS. Histological tests were used to study tissue reaction in experimental animals after implantation of native porcine pericardium and aortic valve leaflets (control), grafts after freezing-thawing and grafts after freezing-thawing with irradiation at a dose of 25 kGy. After 7, 14 days and 1, 3, 6 and 12 months we evaluated the morphological changes of implant structure, inflammatory response of the recipient’s tissue, formation of the capsule and its degree of maturity, the xenogeneic cells survival and recovery of recipient’s surrounding tissue. RESULTS. Comparative analysis has revealed fundamental differences of engraftment indicators and tissue reaction of cryopreserved and irradiated samples from implants after freezing and β-radiation. Cryoradiation processing greatly reduced the immune response to the implantation. Devitalized tissues promoted early stimulation of recipient’s tissues repair, maintained compactness and structural integrity. After a year the border between the implant and connective tissue erased, biomaterial was fully sprouted with recipient’s tissue. The observed changes testify to the integration of implant’s connective tissue, followed by its replacement. CONCLUSION. Our study has confirmed the possibility of using xenogeneic pericardium and aortic valve leaflets, being modified by cryoradiation method to restore soft tissue structures.
منابع مشابه
Difference of xenoreactive immune response and patterns of calcification of porcine and bovine tissues in alpha-gal KO and wild type mouse implantation model
Methods The various xenogeneic tissues (porcine pericardium, aortic valve, aortic wall and bovine pericardium, aortic valve, aortic wall) were fixed in 0.5% glutaraldehyde solution and implanted into the subcutaneous tissue of the wild type-mouse and the KO mouse for 3 months. The implanted mice were harvested and studied for the histopathology, amounts of calcification and immune responses by ...
متن کاملDifferences in xenoreactive immune response and patterns of calcification of porcine and bovine tissues in α-Gal knock-out and wild-type mouse implantation models.
OBJECTIVES Although bioprostheses are widely used in cardiovascular surgery, their durability is limited due to degeneration. Degeneration of bioprostheses limiting its clinical use results from multiple factors, and immune reaction has been considered to be one of the most important factors. The study objectives were to compare the mechanical characteristic differences of porcine and bovine pr...
متن کاملComputational model of aortic valve surgical repair using grafted pericardium.
Aortic valve reconstruction using leaflet grafts made from autologous pericardium is an effective surgical treatment for some forms of aortic regurgitation. Despite favorable outcomes in the hands of skilled surgeons, the procedure is underutilized because of the difficulty of sizing grafts to effectively seal with the native leaflets. Difficulty is largely due to the complex geometry and funct...
متن کاملTranscatheter aortic valve replacement for bioprosthetic aortic valve failure: the valve-in-valve procedure.
2542 B ioprosthetic valves are increasingly used in patients with aortic stenosis. Compared with mechanical valves, bio-prosthetic valves are associated with a lower risk of thrombo-embolic events and do not require long-term anticoagulation. 1,2 However, bioprosthetic valves have limited durability; the best current valves can be expected to degenerate within 10 to 20 years, resulting in steno...
متن کاملApplication of finite element analysis to the design of tissue leaflets for a percutaneous aortic valve.
Percutaneous Aortic Valve (PAV) replacement is an attractive alternative to open heart surgery, especially for patients considered to be poor surgical candidates. Despite this, PAV replacement still has its limitations and associated risks. Bioprosthetic heart valves still have poor long-term durability due to calcification and mechanical failure. In addition, the implantation procedure often p...