Extracorporeal life support for cardiogenic shock: influence of concomitant intra-aortic balloon counterpulsation.
نویسندگان
چکیده
OBJECTIVES Intra-aortic balloon counterpulsation (IABP) during extracorporeal life support (ECLS) for cardiogenic shock may improve pulsatility and coronary perfusion, thereby promoting recovery of cardiac function. However, the risks and benefits of IABP during ECLS in real clinical settings have not been evaluated. This study aims to evaluate the effect of IABP on the early outcome of ECLS for cardiogenic shock. METHODS We evaluated 253 adult patients (aged 58.8 ± 15.3 [mean ± standard deviation] years, 154 males) undergoing ECLS for cardiogenic shock from January 2005 to August 2012. Of them, 60 patients underwent concomitant IABP (IABP group) and 193 underwent ECLS only (control group). In-hospital outcomes were compared using the inverse probability of treatment weighting based on propensity scores. RESULTS The indications for ECLS were low cardiac output after cardiac surgery in 118 patients (46.6%), heart failure in 71 (28.1%), acute myocardial infarction in 49 (19.4%) and others in 15 (5.9%). Successful ECLS weaning rate was significantly higher in the IABP group than in the control group (61.7 vs 42.0%, P = 0.008); however, there was no significant difference in in-hospital mortality between the two groups (68.6 vs 72.0%, P = 0.58). After adjustment for propensity of treatment assignment conditional on baseline characteristics, the IABP group showed a decreased risk of weaning failure (odds ratio [OR] 0.51; 95% confidence interval [CI] 0.28-0.92, P = 0.024) but with a similar risk of in-hospital mortality (OR 0.85; 95% CI 0.46-1.60; P = 0.62) compared with the control group. CONCLUSIONS The use of IABP during ECLS increased a successful ECLS weaning rate, but was not translated into improved survival. Studies on larger populations may verify the survival effect of IABP during ECLS.
منابع مشابه
Percutaneous Mechanical Circulatory Support Devices in Cardiogenic Shock.
Despite a high rate of early revascularization and use of intra-aortic balloon pump counterpulsation therapy, the prognosis of patients with cardiogenic shock has remained poor. In the hopes of improving outcomes, clinicians are increasingly turning to percutaneous left and right mechanical circulatory support devices. Until recently, the evidence base for these devices had consisted only of ob...
متن کاملDoes intra-aortic balloon support for myocardial infarction with cardiogenic shock improve outcome?
CITATION Thiele H, Zeymer U, Neumann FJ, Ferenc M, Olbrich HG, Hausleiter J, Richardt G, Hennersdorf M, Empen K, Fuernau G, Desch S, Eitel I, Hambrecht R, Fuhrmann J, Böhm M, Ebelt H, Schneider S, Schuler G, Werdan K; IABP-SHOCK II Trial Investigators: Intraaortic balloon support for myocardial infarction with cardiogenic shock. N Engl J Med 2012, 367:1287-1296. BACKGROUND In the current inte...
متن کاملProlonged circulatory support with the intra-aortic balloon pump after myocardial infarction.
Circulation was supported by intra-aortic balloon counterpulsation for 30 and 38 days respectively in two patients with cardiogenic shock after acute myocardial infarction. One was flown 1400 km to Cape Town for heart transplantation but died after being weaned from the pump while awaiting a suitable donor. The other underwent successful surgical closure of a ruptured ventricular septum on the ...
متن کاملThe current practice of intra-aortic balloon counterpulsation: results from the Benchmark Registry.
OBJECTIVES This study presents clinical data from the first large registry of aortic counterpulsation, a computerized database that incorporates prospectively gathered data on indications for intra-aortic balloon counterpulsation (IABP) use, patient demographics, concomitant medication and in-hospital outcomes and complications. BACKGROUND The intra-aortic balloon pump (IABP) is widely used t...
متن کاملTransfemoral transcatheter aortic valve implantation in a patient with a severe aortic stenosis and cardiogenic shock requiring intra-aortic balloon pump support
The following paper presents a patient with severe aortic stenosis and severely reduced left ventricular ejection fraction with intra-aortic balloon pump counterpulsation support, who underwent transfemoral aortic valve implantation of a CoreValve prosthesis.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 46 2 شماره
صفحات -
تاریخ انتشار 2014