This paper introduces the concept of the Neutron Silicon Lens (NSL) and provides and update on the experimental results achieved to date. The NSL design is a cylindrical neutron lens based on the use of multiple neutron mirrors supported and separated by silicon wafers. Such lenses would have many applications in both the primary and scattered beams on neutron instruments, and would lead to immediate improvements where the sample to be illuminated is small, as in high pressure or engineering strain scanning instruments.
منابع مشابه
Simulation of a Neutron Detector for Real Time Imaging Applications
Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...
متن کاملبهینهسازی پاسخ دزیمتری نوترون در بازه انرژی حرارتی و سریع برای آشکارساز دیودی
During the last few years, real time gamma and neutron dosimeters have been developed and semiconductor diodes are frequently used in these dosimeters. Semiconductor diodes are used to charged particle detection. For sensitizing the detector to neutrons, a converter layer is contacted on the front surfaces of them. Incident neutrons interact with the converter and produce charged particles that...
متن کاملAn investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy
Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neu...
متن کاملCalculation and evaluation of the vital head organs dose during Neutron Therapy in Tehran Research Reactor using Zubal phantom
In the recent years some studies has been done to consider the capability of Tehran Research Reactor for Boron neutron capture therapy (BNCT). The purpose of this study is to evaluate the sensitive organs dose during the treatment of patient with deep brain tumor by TRR. The calculation has been carried out using the Monte Carlo code MCNPX for ZUBAL head and neck phantom. The method was tested ...
متن کاملشبیهسازی مونت کارلو یک دستگاه پرتودهی نوترونی به منظور تعیین بازده آشکارسازهای نوترونهای حرارتی
In this work, a neutron irradiating system containing six Am/Be neutron sources in a graphite moderator, which produces a relatively high and uniform thermal neutron flux in an irradiating cavity at the center of the system , has been simulated .The thermal neutron flux in the center of the system has then been calculated and compared with experimental results measured in a cavity a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005