Mitigation of Magnetic Field under Double-Circuit Overhead Transmission Line

نویسندگان

  • Osama Elsayed Gouda
  • Adel Z. El Dein
چکیده

This paper studies the effect of various mitigation loop configurations namely: single horizontal mitigation loop (two conductors), two separate horizontal mitigation loops (four conductors) and single vertical mitigation loop (two conductors), on the magnetic field produced by 220 kV double-circuit overhead transmission line. Also, in this paper a further reduction in the magnetic field is achieved by inserting properly-selected capacitors within these mitigation loops. The obtained results indicate that the reduction in the magnetic field by using these mitigation loops largely depends on the arrangements and the locations of these loops with respect to the conductors of 220 kV double-circuit overhead transmission line.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transient Analysis of the Single-Conductor Overhead Lines Connected to Grid-Grounded Arrester under Direct Lightning by Means of GA

In this paper, genetic algorithm-based approach for transient analysis of single transmission line connected to arrester is proposed. In this approach, the lightning channel striking the overhead line is first represented by a current source and this source is truncated by a finite set of frequency harmonies in time domain. Norton equivalent circuit viewed across arrester is then computed by me...

متن کامل

The Effects of the Span Configurations and Conductor Sag on the Magnetic - Field Distribution under Overhead Transmission

Copyright 1996-2012 Researchpub.org. All rights Reserved. 11 Abstract— Ground level electric and magnetic-fields from overhead power transmission lines are of increasingly important considerations in several research areas due to their impact on health and environmental issues. The paper presents a more generalized technique to calculate the magnetic-field generated by power transmission lines...

متن کامل

Calculation of Magnetic Field Produced by OHTL under Normal and Abnormal Conditions

Ground level magnetic field from overhead transmission lines (OHTLs) is of increasingly important considerations in several research areas due to their harmful effect on human health and environment. This paper computes the ground level magnetic field, under normal and abnormal conditions of Egyptian 500-kV single circuit transmission line, in three dimension (3-D) coordinates by using 3-D inte...

متن کامل

Use of Rod Compactors for High Voltage Overhead Power Lines Magnetic Field Mitigation

In the last decades, strengthening the high voltage transmission system through the installation of new overhead power lines has become critical, especially in highly developed areas. Present laws concerning the human exposure to electric and magnetic fields introduce constraints to be considered in both new line construction and existing systems. In the paper, a technique for passive magnetic ...

متن کامل

Application of Intelligent Water Drops in Transient Analysis of Single Conductor Overhead Lines Terminated to Grid-Grounded Arrester under Direct Lightning Strikes

In this paper, Intelligent water drop algorithm (IWD) is used to analyze single overhead line connected to grid-grounded arrester. In this approach, at first Norton’s equivalent circuit of the overhead line over lossy soil is computed by method of moments (MoM) and then for the problem under consideration, a nonlinear equivalent circuit in the frequency domain is proposed. Finally applying inte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013