Temperature changes caused by MR imaging of the brain with a head coil.

نویسندگان

  • F G Shellock
  • J V Crues
چکیده

Tissue heating caused by exposure to RF radiation is a primary safety concern in MR imaging. Therefore, to determine temperature changes caused by high field strength MR imaging of the brain with a head coil, we measured body and skin temperatures in 35 patients immediately before and after clinical MR imaging. MR imaging was performed with a 1.5 T MR system using a 28-cm, open-bore RF transmit/receive head coil specifically designed for examinations of the brain. The average body temperature was 36.6 +/- 0.2 degrees C before MR imaging and 36.6 +/- 0.2 degrees C immediately afterward (mean +/- SD, p = not significant). The average forehead skin temperature increased from 32.6 +/- 0.6 to 32.8 +/- 0.5 degrees C (p less than .01), and the average outer canthus skin temperature increased from 32.1 +/- 0.6 to 32.7 +/- 0.6 degrees C (p less than .01) after MR imaging. The highest skin temperature recorded was 34.2 degrees C, and the largest temperature change was +2.1 degrees There were no statistically significant changes in the average skin temperatures of the upper arm and hand. We conclude that patients undergoing MR imaging of the brain with a head coil at the RF radiation exposure we studied experience no significant changes in average body temperature and statistically significant increases in local (i.e., areas within the head coil) skin temperatures. The observed elevations in skin temperatures were physiologically inconsequential.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

Technique for RF isolation of a pulse oximeter in a 1.5-T MR unit.

1. Uhthoff W. Untersuchungen uber die bei den multiplen Herdsklerose vorkmeiken Augenstorungen. Arch Psychiatrie Nervenkrankheiten 1889; 21 :303-420 2. Edmund J, Fog T. Visual motor instability in multiple sclerosis. Arch Neurol Psychiatry 1955;73:316-323 3. Rasminsky M. The effects of temperature on conduction in demyelinated single nerve fibres. Arch Neuro/1973;28 :287 -292 4. Persson HE, Sac...

متن کامل

Optimization of a four-coil array arrangement for brain therapy by MR-guided transcranial focused ultrasounds

A particularly critical issue for brain therapy with transcranial high-power focused ultrasound (HIFU) is to optimize the accuracy and rapidity of the temperature follow-up during the heating. MRI is a well-suited candidate for temperature monitoring since it offers several parameters such as the proton resonance frequency shift. Up-to-now, temperature scans were achieved using the standard bod...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Neurostimulation systems for deep brain stimulation: in vitro evaluation of magnetic resonance imaging-related heating at 1.5 tesla.

PURPOSE To assess magnetic resonance imaging (MRI)-related heating for a neurostimulation system (Activa Tremor Control System, Medtronic, Minneapolis, MN) used for chronic deep brain stimulation (DBS). MATERIALS AND METHODS Different configurations were evaluated for bilateral neurostimulators (Soletra Model 7426), extensions, and leads to assess worst-case and clinically relevant positionin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 9 2  شماره 

صفحات  -

تاریخ انتشار 1988