Alternating Current Theory -

نویسنده

  • J R Lucas
چکیده

1 November 2001 Alternating Current Theory J R Lucas An alternating waveform is a periodic waveform which alternate between positive and negative values. Unlike direct waveforms, they cannot be characterised by one magnitude as their amplitude is continuously varying from instant to instant. Thus various forms of magnitudes are defined for such waveforms. The advantage of the alternating waveform for electric power is that it can be stepped up or stepped down in potential easily for transmission and utilisation. Alternating waveforms can be of many shapes. The one that is used with electric power is the sinusoidal waveform. This has an equation of the form v(t) = Vm sin(ω t + φ ) If the period of the waveform is T, then its angular frequency ω corresponds to ωT = 2π. (a) Instantaneous value: The instantaneous value of a waveform is the value of the waveform at any given instant of time. It is a time variable a(t). For a sinusoid, Instantaneous value a(t) = Am sin(ω t+ φ ) (b) Peak value: The peak value, or maximum value, of a waveform is the maximum instantaneous value of the waveform. For a sinusoid, Peak value = Am (c) Mean value: The mean value of a waveform is equal to the mean value over a complete cycle of the waveform. It also corresponds to the direct component of the waveform.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement of Power System Condition by Placement of Flexible Alternating Current Transmission Systems devices

Flexible Alternating Current Transmission Systems (FACTS) devices have been used for several targets in power system, one of the main contributions of the devices is improving operation conditions. In this paper, two types of these devices have been placed to raise voltage profile, minimizing system loss and arising loadability. The suggested FACTS devices are: Unified Power Flow Controller (UP...

متن کامل

Improvement of Power System Condition by Placement of Flexible Alternating Current Transmission Systems devices

Flexible Alternating Current Transmission Systems (FACTS) devices have been used for several targets in power system, one of the main contributions of the devices is improving operation conditions. In this paper, two types of these devices have been placed to raise voltage profile, minimizing system loss and arising loadability. The suggested FACTS devices are: Unified Power Flow Controller (UP...

متن کامل

Effect of Transcranial Alternating Current Stimulation on Anxiety and Hemodynamic Response in Patients Undergoing Surgery: A Double-Blind Controlled Clinical Trial

Background: Pre-op anxiety has adverse effects on the patientchr('39')s anesthesia and treatment. Currently, electrical interventions are widely used as non-invasive methods to control pre-op anxiety and may have advantages as compared with medical therapies. This study aimed to determine the effect of transcranial alternating current stimulation on anxiety and hemodynamic response of patients ...

متن کامل

Asymmetric Rectangular Waveform in Stimulation with High Frequency Alternating Current Reduces the Threshold for Neural Conduction Block

Introduction Abnormal neural impulses in the nervous system may lead to various diseases and disabilities. High frequency alternating currents (HFAC) has been used to block the propagation of such impulses and improve the symptoms or disabilities. The technique is safe, reversible, and relatively selective, and its reliability, the optimum stimulation parameters, and elimination of the onset re...

متن کامل

A New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)

This paper presents a new control method for simultaneous compensation of instantaneous reactive power and current harmonics by parallel active filters (PAFs). Reference compensating currents of PAF are calculated using the subtraction of instantaneous power from its average value. In this way, it is possible omitting high/low pass filter(s) from the control circuit of PAF, which usually result...

متن کامل

Micromachining the Aluminium Tubes Using Abrasive Finishing in Alternating Magnetic Field

This study introduced a method based on magnetic field assisted finishing mechanism for micromachining the inner surfaces of Aluminum tubes. In this approach, using the alternating magnetic field of an AC electromotor, abrasive particles were formed as Magnetic Rods (Magnetic Clusters) and surface micromachining was carried out by the dynamic particular pattern made by an alternating magnetic f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001