Reliability of Early Fetal Echocardiography for Congenital Heart Disease Detection: A Preliminary Experience and Outcome Analysis of 102 Fetuses to Demonstrate the Value of a Clinical Flow-Chart Designed for At-Risk Pregnancy Management

ثبت نشده
چکیده

Early fetal echocardiography (EFEC) is a fetal cardiac ultrasound analysis performed between the 12th and 16th week of pregnancy (compared with the usual 18-22 weeks). In the last 10 years, the introduction of “aneuploidy sonographic markers” in screening for cardiac defects has led to a shift from late second to end of the first trimester or beginning of the second trimester of pregnancy for specialist fetal echocardiography. In this prospective study, early obstetric screening was performed between January 2014 and October 2015, using “aneuploidy sonographic markers” following SIEOG Guidelines 2014. These parameters were then collected and strategically combined in an evaluation score to select the group of pregnancies for performing EFEC, in accordance with the American Society of Echocardiography guidelines for fetal Echocardiography. All second-level examinations were performed transabdominally using a 3D convex volumetric probe with frequency range of 4-8 MHz (Accuvix – Samsung). The outcome data included transabdominal fetal echocardiography from 18 weeks to term and after birth. Overall, 99 pregnant women in the first trimester underwent EFEC (95 singleton and 4 twin pregnancies). Specifically, 30 fetuses were evaluated for extra-cardiac anomalies evidenced by obstetric screening (30%), 25 for family history of congenital heart diseases (25%), 8 for family history of genetic-linked diseases (8%), 4 for heart diseases suspected by obstetric screening (4%) and 19 by normal screening (19%). Was detected 11 (10.7%) CHD, when EFEC detected CHD, were compared to those performed later in pregnancy (18 weeks GA-term), a high degree of diagnosis correspondence was evidenced. The higher sensitivity value of EFEC vs late-FE, in comparison with the post-natal value, coupled with the high EFEC specificity shown vs both the end points, enabled us to consider it as a really reliable diagnostic technology, at least in perienced hands. The introduction of a key combination of the more sensitive obstetric and cardiologic variables should facilitate the formulation of a possible flow-chart as a guide for CHD at-risk pregnancies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

I-44: Increased Nuchal Translucency at 11-14 Weeks of Gestation As A Marker for Adverse Pregnancy Outcomes

Background: To evaluate the association of increased fetal nuchal translucency( NT) and adverse pregnancy outcomes. Materials and Methods: In a prospective study, 2221 women who were conceived after Assisted Conception were investigated by sonography independent of multiplicity between 11 and 13 weeks' gestation. We performed 2899 NT examinations during the study period(21 March 2010 to 21...

متن کامل

Fetal Echocardiography Indications: A Single- Center Experience

Background Congenital heart disease (CHD) is the most common lethal congenital anomaly. Early diagnosis of CHD by fetal echocardiography based on maternal and fetal indications is important and lifesaving. The aim of study was to assess the referral aspects of pregnant women to pediatric cardiologist. Materials and Methods This was a retrospective cross-sectional study on 250 documents of refer...

متن کامل

O-28: Detection of Fetal Major Structural Abnormalities with US in ART Patients during One Year

Background: The aims were to determine the diagnostic accuracy of ultrasound sonography in detecting major structural anomalies on all patients who conceived during a year of infertility treatment [assisted reproductive technology (ART) or non-ART treatments] at the Royan Institute, and to study the outcome of cases with nuchal translucency (NT) ≥ 95th centile in the first trimester of pregnanc...

متن کامل

بررسی شیوع و فاکتورهای مستعدکننده مادری و جنینی در مرگ‌های داخل رحمی جنین

Background and purpose: Around three million fetuses lose their life before birth each year. Recognizing the risk factors of these deaths could help in controlling and preventing at least a number of them. This study was conducted to determine the risk factors for uterine deaths. Materials and methods: This cross-sectional study was conducted in 225 cases of fetus uterine deaths aged >20 week ...

متن کامل

CONGENITAL HEART DISEASE Clinical impact of first and early second trimester fetal echocardiography on high risk pregnancies

Objective: To evaluate the clinical impact of fetal echocardiography before 16 weeks’ gestation on the management of pregnancies with fetuses at risk of congenital heart disease. Design and setting: Observational study in a fetal medicine unit. Participants and methods: 222 consecutive women with high risk pregnancies (230 fetuses) underwent transabdominal fetal echocardiography at a median ges...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017